Gost Phantom Скачать руководство пользователя страница 1

      

           GOST Phantom 

 Instal Programming Guide 

[email protected]

 or (954) 565-9898 

1

          Congratulations on the installation of the GOST Phantom wireless vessel security and monitoring system. The product is designed to 
wirelessly communicate with the assorted security and monitoring zones aboard the vessel.  This provides reliable protection while alerting 
contacts of events via voice message and/or text messages, giving the owner true piece of mind. This guide is provided to bring the installer 
through the basic installation, setup, and wireless programming of the GOST Phantom. It is recommended that the installer read this entire 
guide fully before beginning.  It is important that the installer has an understanding of marine electrical fundamentals and adheres to the NMEA 
standards of marine electronics.   Figure 1 below identifies the keypad functions and LEDs on the front of the panel.   
The GOST Phantom allows programming for: 
 

 

 64 Wireless zones from security to utility monitoring throughout vessel  

 

 8 wireless relays to control virtually any AC/DC switch, deck lights, sirens, strobes, ice makers, etc. 

 

 4 wireless keypads for additional arming control from staterooms, entry points, crew quarters, etc. 

 

 4 repeaters to double the wireless range commonly used on metal boats and vessels greater that 125 ft. 

 

 4 Siren/Strobes for simple implementation in various points around exterior of vessel 

 

 2 doorbell zones for notification at boarding entry points where individuals come aboard the vessel. 

 

 2 Independent partitions to arm/ disarm different areas of vessel such as Living Quarters and Crew/Utility Areas. 

 

 

Figure 1 

Location Considerations 

     The placement of the GOST Phantom aboard the vessel should be well thought out and reviewed with the yacht owner/crew prior to 
installation. The installer must make sure that adequate security concerns, end user ease of use, and functionality of speakerphone are taken 
into account. Reference the following guidelines before drilling any holes or running any wires.   

 

Interior of boat, away from any direct moisture 

 

Common areas such as the salon, interior helm, or similar primary entry areas of the vessel. 

 

Easy accessibility for someone boarding the boat  

 

On larger vessels greater than 100ft (Approx. 30 meters) try to keep the head unit towards midship to maximize wireless range 

 

Accommodate for wire run accessibility from rear of panel to power source and GSM/Satellite phone*. 
*When connecting to third party satellite phone communicator. 

 
Mounting  

     The GOST Phantom head unit conveniently pivots and detaches off its upper hinges for ease of installation.  To access the mounting base 
plate, unscrew the cover lock down screws from the bottom side as so they are free hanging.  Now gingerly fold the bottom apart from the top 
hinge (Figure 2 right).  Assure that you unplug or plug in the battery cable to the rear of the board when removing or securing the cover 
(respectively).    Screw in the mounting plate at any of the mounting holes in Figure 2 at the orange dots.  The mounting plate also has 

“Mounting 

Security

” option that can be used to alarm the GOS

T Phantom if it is opened or torn off the wall (Figure 2).   

Содержание Phantom

Страница 1: ...ls come aboard the vessel 2 Independent partitions to arm disarm different areas of vessel such as Living Quarters and Crew Utility Areas Figure 1 Location Considerations The placement of the GOST Phantom aboard the vessel should be well thought out and reviewed with the yacht owner crew prior to installation The installer must make sure that adequate security concerns end user ease of use and fun...

Страница 2: ...rom brief power switchovers if Yes Use the supplied PA 7 110 240 VAC 7 5 VDC transformer to power the GOST Phantom Make sure the VAC outlet is constantly hot and does not get shut off when the boat is not being used If No Power the GOST Phantom with the step down 7 5VDC converter from the vessels constant domestic 12 24VDC batteries Note Power should be denied when making all electrical connection...

Страница 3: ...aging available The GOST Phantom is defaulted to report events thru this communicator as the primary method If you are using either a Separate GSM communicator Insight Package or Satellite phone it will be necessary to adjust the default system setting 08 System Setup 09 Communicator Page 18 If the Installer is using the GOST Phantom in conjunction with a GSM communicator or Satellite phone alarms...

Страница 4: ...one menu appears when entering the Installer code a different menu appears review menu flow charts in Figure 5 and Figure 6 respectively An example of this is that the master coder can add delete other user codes while the installer code cannot Conversely the installer code can add delete zones Relays etc while the master code can only modify the labels Review these flow charts thoroughly before p...

Страница 5: ...GOST Phantom Installation Programming Guide support gostglobal com or 954 565 9898 5 Figure 5 ...

Страница 6: ...GOST Phantom Installation Programming Guide support gostglobal com or 954 565 9898 6 Figure 6 ...

Страница 7: ... Figure 8 that describes how to enter labels a zone the process is the same for entering any text label You do not need to do this process now it is important to understand the functionality of it Function 1 Press the center clear button to wipe out existing verbiage zone 1 user 2 area 1 etc Function 2 Enter the digits to the right on Figure 8 for the respective letter or character As an example i...

Страница 8: ... you change the master code User 1 from the default 1234 only the new master code will be able to access the user profile The three types of key fobs that are compatible with the GOST Phantom shown in Figure 9 below Note For every user code programmed to the GOST Phantom there can be a key fob However for every key fob programmed there must be a user code associated to it Figure 9 To program the u...

Страница 9: ... install all zones individually as they move through the installation It is the quickest and most efficient way to work thru an installation Zone Programming is the first option inside the system setup Installer menu When programming the assorted zones into corresponding zone numbers it is best to group like zones within close range of each other As an example all door contacts could be zones 1 4 ...

Страница 10: ... opens and closes accordingly There are many different definitions of zone types Thoroughly review the typical zone definitions for the different types of zones in Table 1 If you still have questions after reviewing the table see the standard definitions below it Press next and ok to navigate and select the desired zone type according to the general guidelines below for each style zone ...

Страница 11: ...alarm 24 7 on opening Delay fire 80 second Delay on breach before alarm 24 7 Assigning Zones to Areas An Area of the GOST Phantom can also be described as a partition The GOST Phantom has two partitions This feature allows two independent areas of the boat to be armed and disarmed An example of this would be when an owner wants to keep the living quarters aboard his boat independent of the Engine ...

Страница 12: ... allows the Output to activate following the Bell cut off delay The bell cut off delay is the amount of time that the internal 90 decibel siren of the GOST Phantom will sound before shutting off The event scares away would be thieves while shutting off after a period of time as to not annoy your fellow dock mates The unit stays in alarm and will re initialize if a zone is breached again By default...

Страница 13: ...GOST Phantom Installation Programming Guide support gostglobal com or 954 565 9898 13 ...

Страница 14: ...rm the system from different areas of the boat Figure 12 It comes in handy if client wants to keep the GOST Phantom covert It also provides additional control stations for Staterooms crew quarters and secondary entry areas Power up the keypad in the designated area according to the criteria in the included directions And program according to the following directions Figure 12 ...

Страница 15: ...ter GMM IP65 RP is used to double the wireless range of the GOST Phantom s assorted zones outputs or wireless keypads It is used on vessels usually 80 Feet where diamond plating metallic sound proofing or multiple bulkheads reduce wireless range The GOST Phantom is compatible with a maximum of four repeaters ...

Страница 16: ... be used to deter theft Common locations are under gunwales aboard the boat or mounted to pilings on the dock next to the boat Interior versions are also available for farther away staterooms where people need to get waken up on alarm Note that this device is its own solution specifically designated for this area of programming If using a separate siren or light triggering application it should be...

Страница 17: ... larger boats with boarding stairs like to have a wireless door bell to alert the GOST Phantom System and their crew that someone is waiting to board the vessel It is suggested that a GMM IP67 DC with a GNT Pushbutton be used for this application as it can be easily moved and mounted for different docking scenarios ...

Страница 18: ...GOST Phantom Installation Programming Guide support gostglobal com or 954 565 9898 18 08 Delays Tones ...

Страница 19: ...ia RJ 11 to secondary GSM or Satellite phone dialer You must now go into Section Programming and modify Sections 2007 and 2037 1 Press Exit until you get to the home screen and hold down the 0 key for three seconds 2 Enter the installer Code 1111 3 Enter Section 2007 and the defaults will display as 23 56 4 Press the numbers 1 2 3 5 and 6 and it will now display 1 5 Press to confirm the change and...

Страница 20: ...GOST Phantom Installation Programming Guide support gostglobal com or 954 565 9898 20 ...

Страница 21: ... this area of programming unless directed by the owner of if the installer has security concerns of someone changing installer codes on the system Consult GOST support if further information is needed on this section 11 System Test This area can be used after the install is complete to test assorted wireless entities of the system ...

Страница 22: ...g the trouble by pressing the left menu action key you view the trouble and press ok to stop the beeping See the Trouble Display area below in Table 2 to see all of the possible troubles that could appear Table 2 Installer Quick Keys Resets This area of the system assists installers in resetting values to factory defaults cancelling communication resetting outputs or hearing audible zone Open Clos...

Страница 23: ...ndary GSM module See 08 System Setup 09 Communicator FAQ 3 The Onboard GSM Module will not stop displaying a trouble for the unused Sim 2 This message comes up when at one point of another a card has been placed in Sim 2 The module needs a reset Go to section 9002 to factory reset this module only It will then reboot the module and accommodate for only the sim card inserted and leave the rest stag...

Отзывы: