Gossen MetraWatt Z227O Скачать руководство пользователя страница 3

3

Gossen Metrawatt GmbH

Z227O

3 The Instrument

3.1

Scope of Delivery

Please check for completeness.

3.2

Symbols on the Instrument and 
the Included Accessories

3.3

Technical Data

4 Operation

Make sure that the probes are compatible 
with the utilized measuring instrument. Com-
pare the technical data and all other specifi-
cations included in the documentation for 
the measuring instrument to this end.

Connect the probes as specified in the doc-
umentation for the measuring instrument.

Perform measurement as described in the 
documentation for the utilized measuring 
instrument. Contact must be established by 
applying an appropriate amount of pressure.

Attention!

!

The probes may only be used for 
four-wire measurements (milliohm 
measurements) in measuring cate-
gory CAT II.

If necessary, use the included S hooks for 
cable management. They can be used to 
hold 2 measurement cables together.

5 Maintenance

5.1

Cleaning

No special maintenance is required. Keep 
outside surfaces clean. Use a cloth for 
cleaning, which has been slightly dampened 
with water.

Attention!

!

Avoid the use of cleansers, abrasives 
or solvents.

1

Set of test probes, 1 red and 1 black 

3

S  hooks

1

Operating Instructions (this document)

Warning concerning a point of 
danger (attention, observe 
documentation!)

Double insulation 
(protection category II)

European conformity marking

The device may not be disposed of 
with household trash. Current and 
further information is available on 
our website at http://www.gossen-
metrawatt.com under the search 
terms “WEEE” and “environmental 
protection”.

Ambient Conditions

Operating 
temperature:

-20 ... +50 °C

Storage 
temperature:

-25 ... +75 °C

Relative 
humidity:

Max. 75% 
No condensation 
allowed

Elevation:

Max. 2000 m

Electrical Safety

Measuring 
category:

CAT II 300 V 10 A

Pollution degree:

2

!

Mechanical Design

Plug:

4 mm,
90° angled 
safety plug

Length (overall):

120 cm

Weight: Approx. 

180 

g

Strain relief:

> 100 N

Содержание Z227O

Страница 1: ...he instrument Carefully and completely read and adhere to these operating instructions The respective document can be found at http www gossenmetrawatt com Retain the document for future refer ence Read and adhere to the operating instructions included with your measur ing instrument Observe and comply with all safety regu lations which are applicable for your work environment Wear suitable and ap...

Страница 2: ...of four pole technology and com pensate for erroneous influences during measurement resulting from cable and con tact resistances Safety of the operator as well as that of the instrument is only assured when it s used for its intended purpose 2 2 Use for Other than Intended Purpose Using the instrument for any purposes other than those described in these operating instructions is contrary to use f...

Страница 3: ...an be used to hold 2 measurement cables together 5 Maintenance 5 1 Cleaning No special maintenance is required Keep outside surfaces clean Use a cloth for cleaning which has been slightly dampened with water Attention Avoid the use of cleansers abrasives or solvents 1 Set of test probes 1 red and 1 black 3 S hooks 1 Operating Instructions this document Warning concerning a point of danger attentio...

Страница 4: ...part Z227F spring loaded contact pins for Kelvin probes Orders can be placed by contacting our sales department See below for contact details Information concerning replacement can be found in the supplementary sheet included with the replacement part 6 Repair and Replacement Parts Service Calibration Center and Rental Instrument Service If required please contact This address is only valid in Ger...

Отзывы: