Gossen MetraWatt Z227O Скачать руководство пользователя страница 1

Operating Instructions

Z227O

Probes for 4-Wire Measurement

3-447-097-03

2/3.21

1

Table of Contents

1 Safety Instructions............................. 1

2

Applications ....................................... 2

2.1 Intended Use / 

Use for Intended Purpose .............. 2

2.2 Use for Other than Intended 

Purpose ......................................... 2

2.3 Liability and Guarantee................... 2
2.4 Opening the Instrument / Repairs... 2

3

The Instrument................................... 3

3.1 Scope of Delivery ........................... 3
3.2 Symbols on the Instrument and the 

Included Accessories ..................... 3

3.3 Technical Data ............................... 3

4

Operation ........................................... 3

5

Maintenance ...................................... 3

5.1 Cleaning......................................... 3
5.2 Replacing the Spring-Loaded 

Contact Pins .................................. 4

6

Repair and Replacement Parts
Service, Calibration Center and 
Rental Instrument Service ................. 4

7

CE Declaration ................................... 4

1 Safety Instructions

Observe this documentation, in particular all 
included safety information, in order to pro-
tect yourself and others from injury, and to 
prevent damage to the instrument.

Carefully and completely read and 
adhere to these operating instructions.
The respective document can be found 
at http://www.gossenmetrawatt.com. 
Retain the document for future refer-
ence.

Read and adhere to the operating 
instructions included with your measur-
ing instrument.

Observe and comply with all safety regu-
lations which are applicable for your 
work environment.

Wear suitable and appropriate personal 
protective equipment (PPE) whenever 
working with the instrument.

Use the instrument for milliohm mea-
surements only (four-wire measurement) 
in measuring category CAT II.

Only use the instrument and its accesso-
ries in compliance with the specified 
technical data and under the specified 
conditions (ambient conditions, IP pro-
tection code, measuring category etc.).

The instrument may only be used as long 
as it’s in good working order.
Inspect the instrument before use. Pay 
particular attention to damage, broken 
insulation or kinked cables.
Damaged components must be 
replaced immediately.

Содержание Z227O

Страница 1: ...he instrument Carefully and completely read and adhere to these operating instructions The respective document can be found at http www gossenmetrawatt com Retain the document for future refer ence Read and adhere to the operating instructions included with your measur ing instrument Observe and comply with all safety regu lations which are applicable for your work environment Wear suitable and ap...

Страница 2: ...of four pole technology and com pensate for erroneous influences during measurement resulting from cable and con tact resistances Safety of the operator as well as that of the instrument is only assured when it s used for its intended purpose 2 2 Use for Other than Intended Purpose Using the instrument for any purposes other than those described in these operating instructions is contrary to use f...

Страница 3: ...an be used to hold 2 measurement cables together 5 Maintenance 5 1 Cleaning No special maintenance is required Keep outside surfaces clean Use a cloth for cleaning which has been slightly dampened with water Attention Avoid the use of cleansers abrasives or solvents 1 Set of test probes 1 red and 1 black 3 S hooks 1 Operating Instructions this document Warning concerning a point of danger attentio...

Страница 4: ...part Z227F spring loaded contact pins for Kelvin probes Orders can be placed by contacting our sales department See below for contact details Information concerning replacement can be found in the supplementary sheet included with the replacement part 6 Repair and Replacement Parts Service Calibration Center and Rental Instrument Service If required please contact This address is only valid in Ger...

Отзывы: