22
GOSSEN Foto- und Lichtmeßtechnik
After each measurement using the measuring but-
ton
the following data are stored and displayed:
– the symbol ZONE and the last measured value
are displayed on the left
– the number of measurements made are
displayed on the right (4 measurements in the
example)
– on the zone scale the currently measured
values are indicated (identical values only
once) and the average of the brightest and
the darkest spot as a flashing dot
When the measuring process is completed and
you then switch over to the function „ambient light“
and the desired measuring function, the value
measured in the zone V is displayed as shutter
speed/f-stop combination. Additionally, the flashing
ZONE symbol is displayed.
Now, you can select further shutter speed/f-stop
combinations using the setting wheel.
If, by mistake, you take a zone measurement in
the incident light mode (flat or spherical diffuser),
you are reminded by the flashing diffusor symbol
that you have to set the diffuser ring to 1° spot
metering.
Note down the subject contrast for the film
development and adjust the development time in
accordance with the contrast range.