Cable Database Management
The instrument includes a cable database which is filled with entries for 32 different cable
types at the factory. The appropriate cable entry can be selected for measurements (
thus making it unnecessary to manually enter cable data.
The 32 predetermined cable types represent the maximum possible number of entries. The
cable database can be managed, e.g. edited, in the software. The edited database must
then be transferred back to the instrument.
The entries in the cable database can also be exported in order to back them up and/or
transfer them to other METRACABLE MANAGER installations, and thus to other instruments
as well. Entries are exported and imported as a proprietary copper parameters file with the
extension “.CUP”. Compatible CSV files can also be used.
Note!
The cable database is not permanently stored in the program. It has to be loaded from
the instrument or the PC each time it’s needed. After editing, it has to be transferred
back to the instrument and/or saved to the PC. Changes are otherwise lost.
•
Loading the Cable Database from the Instrument to the Software
•
Manually Adding, Deleting and Editing Cable Parameters
•
Exporting the Cable Database from the Software to the PC
•
Importing the Cable Database from the PC to the Software
•
Uploading the Cable Database from the Software to the Instrument
Loading the Cable Database from the Instrument to the Software
Load the cable database from your instrument to the software, after which it can be edited.
The cable database must then be transferred back to the instrument or saved at the PC (see
the following sections).
There’s a cable database in the instrument (included as a default feature).
The instrument and the PC/METRACABLE MANAGER are connected to each other
20.
1. Select
Cable Parameters
from the menu.
The
Cable Parameters
dialog appears.
2. Click the
Load Cu Parameters from METRACABLE
button.
The data are imported to the software from the instrument.
The entries can now be edited.
Manually Adding, Deleting and Editing Cable Parameters
32 cable types are specified in the cable database as a default feature. Existing cable types
can be edited and entries can be deleted in order to add new cable types. entries are
deleted by removing the values from the
Cable Name
and
VF
fields.
1. Select
Cable Parameters
from the menu.
The
Cable Parameters
dialog appears.
2. Select the field to be edited from the list with a double-click.
The selected entry turns blue.