SFV & SFEV SERIES X‐PROOF PUMPS
OM-06628
SAFETY
PAGE A - 3
The electrical power used to operate
this pump is high enough to cause inju
ry or death. Make certain that the control
handle on the control box is in the OFF
position and locked out, or that the pow
er supply to the control box has been
otherwise cut off and locked out, before
attempting to open or service the pump
assembly. Tag electrical circuits to pre
vent accidental start‐up.
Never attempt to alter the length or re
pair any power cable with a splice. The
pump motor and cable must be com
pletely waterproof. Injury or death may
result from alterations.
All electrical connections must be in ac
cordance with The National Electric
Code and all local codes. If there is a
conflict between the instructions pro
vided and N.E.C. Specifications, N.E.C.
Specifications shall take precedence.
All electrical equipment supplied with
this pump was in conformance with
N.E.C. requirements in effect on the
date of manufacture. Failure to follow
applicable specifications, or substitu
tion of electrical parts not supplied or
approved by the manufacturer, can re
sult in severe injury or death and void
warranty.
After the pump has been installed, make
certain that the pump and all piping or
hose connections are secure before op
eration.
Approach the pump cautiously after it
has been running. Although the motor is
cooled by dispersing heat through the
motor housing cooling fins into the liq
uid being pumped, normal operating
temperatures can still be high enough
to cause burns. The temperature will be
especially high if operated against a
closed discharge valve. Never operate
against a closed discharge valve for
long periods of time.
Do not remove plates, covers, gauges,
pipe plugs, or fittings from an over
heated pump. Vapor pressure within the
pump can cause parts being disen
gaged to be ejected with great force. Al
low the pump to completely cool before
servicing.
If the pump is used to handle liquids
which may cause illness or disease
through direct exposure, take neces
sary precautions during maintenance
and repair to prevent personal contam
ination.
The motor powering this pump is ap
proved by either CSA and/or FM for Class
1, Division 1, Groups C and D environ
ments.
Refer to the nameplate on your