![GORMAN-RUPP GHA SERIES Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/gorman-rupp/gha-series/gha-series_installation-operation-and-maintenance-manual_2246693037.webp)
GHA SERIES
OM--04621
PAGE E--15
MAINTENANCE AND REPAIR
105 MIN.
1.23 FULLY OUT
125
1.09
150
.91
175
.73
200
.55
220 MAX.
.37 FULLY IN
55 MIN.
1.23 FULLY OUT
75
.89
100
.51
110 MAX.
.37 FULLY IN
50 MIN.
1.17 FULLY OUT
100
.93
125
.83
150
.72
175
.61
200
.50
240 MAX.
.31 FULLY IN
30 MIN.
1.17 FULLY OUT
50
.88
75
.57
95 MAX.
.31 FULLY IN
100 MIN.
.60 FULLY OUT
125
.51
150
.42
175
.33
200
.23
225 MAX.
.16 FULLY IN
CRACKING
PRESSURE
(PSI)
GC, GF,
GH, GJ
PUMP
HYDRAULIC
SIZE
SINGLE
SPRING
OPTION CODE
DOUBLE
SPRING
OPTION CODE
DIMENSION
“A” (INCHES)
Fig. E-7)
CRACKING
PRESSURE
(PSI)
50 MIN.
.60 FULLY OUT
75
.47
100
.33
130 MAX.
.16 FULLY IN
DIMENSION
“A” (INCHES)
Fig. E-7)
STD
25D
25G
25J
25S
25U
STD
25D
25G
25J
25S
25U
STD
25D
25G
25J
25S
25U
25A
25E
25H
25K
25T
25V
25A
25E
25H
25K
25T
25V
25A
25H
25K
25T
25V
JJ, JL,
JP, NK,
NM, NP
RM, RP,
RR, RS
Table E-2. Cracking (Valve Opening) Settings ( Denotes Factory Setting)