OM-00675
10 SERIES
MAINTENANCE & REPAIR
PAGE E - 9
PUMP AND SEAL DISASSEMBLY
AND REASSEMBLY
Review all SAFETY information in Section A.
Follow the instructions on all tags, label and de
cals attached to the pump.
This pump requires little service due to its rugged,
minimum‐maintenance design. However, if it be
comes necessary to inspect or replace the wearing
parts, follow these instructions which are keyed to
the sectional views (see Figures 1 through 4) and
the accompanying parts lists.
This manual will alert personnel to known proce
dures which require special attention, to those
which could damage equipment, and to those
which could be dangerous to personnel. However,
this manual cannot possibly anticipate and provide
detailed precautions for every situation that might
occur during maintenance of the unit. Therefore, it
is the responsibility of the owner/maintenance per
sonnel to ensure that
only
safe, established main
tenance procedures are used, and that any proce
dures not addressed in this manual are performed
only
after establishing that neither personal safety
nor pump integrity are compromised by such prac
tices.
Most service functions, such as wear plate, impel
ler, and seal replacement, may be performed by
draining the pump and removing the back cover
assembly. However, the following instructions as
sume complete disassembly is required.
Before attempting to service the pump, switch off
the engine ignition and disconnect the positive bat
tery cable to ensure that the pump will remain inop
erative. Close all valves in the suction and dis
charge lines.
For engine disassembly and repair, consult the lit
erature supplied with the engine, or contact your
local engine representative.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Switch off the engine ignition and
disconnect the positive battery
cable to ensure that the pump will
remain inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.
Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam
age to equipment. The bail is intended
for use in lifting the pump assembly
only. Suction and discharge hoses and
piping must be removed from the pump
before lifting.
Back Cover And Wear Plate Removal
(Figure 3)
Before attempting to service the pump, remove the
pump casing drain plug (42) and drain the pump.
Clean and reinstall the drain plug. The wear plate
(41) and check valve (57) are easily accessible and
may be serviced by removing the back cover as
sembly (49).
Remove the cover clamp screw (46) and clamp bar
(45) securing the back cover. Pull the back cover
and assembled wear plate from the pump casing.
Inspect the back cover gasket (54) and replace it if
damaged or worn.
Содержание 14C2-F3L
Страница 6: ......
Страница 16: ......
Страница 26: ...10 SERIES OM 00675 MAINTENANCE REPAIR PAGE E 2 PARTSPAGE SECTION DRAWING Figure 1 Pump Model 14C2 F3L ...
Страница 28: ...10 SERIES OM 00675 MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION Figure 2 46143 158 Power Unit Kit ...
Страница 30: ...10 SERIES OM 00675 MAINTENANCE REPAIR PAGE E 6 SECTION DRAWING Figure 3 14C2 SAE 4 10 Pump End Assembly ...
Страница 43: ......