S SERIES PUMPS
OM-07264
MAINTENANCE AND REPAIR
PAGE E - 22
To fill the seal cavity, remove the pipe plug (6) and
add the recommended grade of submersible
pump oil. Apply `Loctite Pipe Sealant With Teflon
No. 592.' or equivalent to the threads of the pipe
plug, before reinstalling the plug.
See Table E-2 for quantity of lubricant when lubri
cating a dry (overhauled) pump. See Table 3 for lu
bricant specifications.
The grade of lubricant used is critical to the opera
tion of this pump. Use premium quality hydraulic oil
as specified in the following table. Oil must be
stored in a clean, tightly closed container in a rea
sonably dry environment.
Table E-2. Oil Quantity
Pump Model
Seal Cavity
Motor Cavity
S3A
56 ounces (1,6 liters)
24 ounces (0,7 liters)
Table E-3. Pump Oil Specifications
Specifications:
Type
Premium high viscosity index, anti‐wear hydraulic oil
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Viscosity (SSU @ 104
_
F [40
_
C])
110 to 155
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dielectric
26,000 (volts‐min)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Acceptable alternate suppliers:
Gulf Oil Company
Gulf Harmony AW Hydraulic Fluid MG 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Texas Oil Company
Rando HD 32 or HD AZ 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sun Oil Company
Sunvis 816 or 916
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BP (Also Boron)
Energol‐HLP 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shell Oil Company
Tellus 32, Tellus T‐23 or T32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Viscosity (SSU @ 210
_
F [100
_
C])
40 to 50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recommended supplier:
Gulf Oil Company
Gulf Harmony 32 AW
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ARCO
Duro 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Exxon (Also Esso)
Nuto H 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Petro‐Canada
Harmony HVI 22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor Housing Cavity
With the pump in an upright position, remove the
pressure relief valve (29) on the top of the pump.
See Table 2 and add the recommended grade of
lubricant (Table E-3) to the motor cavity.
Maintain
the oil at this level
. Apply `Loctite Pipe Sealant
With Teflon No. 592' or equivalent sealant to the
threads of the relief valve (29). Reinstall and tighten
the valve.
Never attempt to fill the motor cavity
through the drain plug (7) opening. A vol
ume of air must be trapped above the mo
tor to permit thermal expansion of the mo
tor oil.