GORMAN-RUPP PUMPS Roto-Prime RD Series Скачать руководство пользователя страница 3

OM-03989

RS AND RD SERIES PUMPS

PAGE I - 1

INTRODUCTION

INTRODUCTION

Thank You

 for purchasing a Gorman‐Rupp RS or

RD Roto‐Prime

 

Series Pump. 

Read this manual

carefully to learn how to safely install and operate
your pump. Failure to do so could result in personal
injury or damage to the pump.

A set of three manuals accompanies your pump.
Each set consists of three parts; the Installation/
Operation Manual contains essential information
on installing and operating the pump. However,
since pump installations are seldom identical,
some of the information only summarizes general
recommendations and practices required to in­
spect, position, and arrange the pump and piping.

The Parts List Manual provides performance
curve(s), a pump model cross‐section drawing,
and parts list for your pump.

The Maintenance and Repair Manual provides
troubleshooting and maintenance instructions re­
quired to properly diagnose operational problems,
and to service the pump components. Contact the
factory for the authorized repair facility closest to
you.

This pump is a Roto‐Prime

 self‐priming centrifu­

gal petroleum pump, designed to handle 

petro­

leum products only

. It incorporates an integral va­

riable‐capacity vane pump which automatically
evacuates air and vapor from the suction line. This
pump should 

not 

be used to handle water or other

non‐petroleum liquids. For specific service, con­
tact your Gorman‐Rupp distributor or the Gorman‐
Rupp Company.

The basic pump is not furnished with a mounting
base and power source; however, these items are

available from the factory as optional equipment.
The pump is designed to be driven by an explo­
sion‐proof motor with a maximum full load speed
of either 1750 RPM (RS Series) or 3450 RPM (RD
Series).

Because pump installations are seldom identical,
this manual cannot possibly provide detailed in­
structions and precautions for every aspect of
each specific application. Therefore, it is the re­
sponsibility of the owner/installer of the pump to
ensure that applications not addressed in this
manual are performed 

only

 after establishing that

neither operator safety nor pump integrity are com­
promised by the installation. Pumps and related
equipment 

must

 be installed and operated ac­

cording to all national, local and industry stan­
dards.

If there are any questions regarding the pump
which are not covered in this manual or in other lit­
erature accompanying the unit, please contact
your Gorman‐Rupp distributor or the Gorman‐
Rupp Company:

The Gorman‐Rupp Company

P.O. Box 1217

Mansfield, Ohio  44901-1217

Phone: (419) 755-1011

or:

Gorman‐Rupp of Canada Limited

70 Burwell Road

St. Thomas, Ontario N5P 3R7

Phone: (519) 631-2870

CONTENTS

SAFETY - SECTION A
INSTALLATION - SECTION B

GENERAL INFORMATION

PAGE B - 1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PUMP DIMENSIONS

PAGE B - 1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PREINSTALLATION INSPECTION

PAGE B - 1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

POSITIONING PUMP

PAGE B - 2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

GROUNDING

PAGE B - 2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SUCTION AND DISCHARGE PIPING

PAGE B - 2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SUCTION LINES

PAGE B - 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DISCHARGE LINES

PAGE B - 6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ALIGNMENT

PAGE B - 7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Содержание Roto-Prime RD Series

Страница 1: ...OM 03989 January 21 1994 Rev D 05 10 12 THE GORMAN RUPP COMPANY MANSFIELD OHIO GORMAN RUPP OF CANADA LIMITED ST THOMAS ONTARIO CANADA Printed in U S A www grpumps com 1994 The Gorman Rupp Company RS A...

Страница 2: ...rial number and e mail address required RECORD YOUR PUMP MODEL AND SERIAL NUMBER Please record your pump model and serial number in the spaces provided below Your Gorman Rupp distributor needs this in...

Страница 3: ...con tact your Gorman Rupp distributor or the Gorman Rupp Company The basic pump is not furnished with a mounting base and power source however these items are available from the factory as optional eq...

Страница 4: ...actory specifications the war ranty will become void and any claim will be de nied The following are used to alert personnel to procedures which require special attention to those which could damage e...

Страница 5: ...ual 2 Shut off the incoming power to the motor and lock it out or take other action to ensure that the pump will remain inoperative 3 Allow the pump to completely cool if overheated 4 Check the tempe...

Страница 6: ...in this manual before restarting the pump Do not install and operate a non explo sion proof motor in an explosive atmo sphere Install connect and operate the motor in accordance with The Na tional El...

Страница 7: ...imit the incoming pres sure to 50 of the maximum permissible operating pressure shown on the pump performance curve For further assistance contact your Gorman Rupp distributor or the Gorman Rupp Compa...

Страница 8: ...s occurs after the pump and piping are properly secured contact the factory to obtain optional springs for the priming pump group grind If the vibration is not corrected the tubing could fatigue and r...

Страница 9: ...ration decreased bearing life and increased shaft and seal wear If hose type lines are used they should have adequate support to secure them when filled with liquid and under pressure Gauges Most pump...

Страница 10: ...to protect the pump from acciden tal damage a commercially available 80 mesh screen should be installed in the suction line Make certain that the total open area of the screen is at least three or fou...

Страница 11: ...trained air to escape from the liquid before it is drawn into the suction inlet If two suction lines are installed in a single sump the flow paths may interact reducing the efficiency of one or both p...

Страница 12: ...required on the pump to facilitate installation and proper function of the Air Release Valve it is recommended that this be ordered as a factory installed option only The Air Release Valve works in co...

Страница 13: ...ipment Misalign ment will occur in transit and handling Pumps must be checked and realigned before operation Before checking alignment tighten the foundation bolts The pump casing feet and or pedestal...

Страница 14: ...llel alignment If the coupling is misaligned use a feeler gauge between the coupling and the straightedge to measure the amount of misalign ment Figure 5 Aligning Non Spider Type Couplings Do not oper...

Страница 15: ...Make sure that the piping connec tions are tight and that the pump is securely mounted Check that the pump is properly lubri cated see LUBRICATION in MAINTENANCE AND REPAIR Never operate this pump unl...

Страница 16: ...all amount of liquid See Figure 2 for the theory of priming pump operation FULL PRIMING SPRING FULLY EXTENDED SLIDE AT BOTTOM MAXI MUM VAPOR EVACUATION PARTIAL PRIMING SPRING SLIGHTLY COMPRESSED SLIDE...

Страница 17: ...e Valve Connected To Roto Prime Pump The Air Release Valve is designed with an air valve in the head of the assembly and a sump valve in the base of the assembly These valves are controlled by a commo...

Страница 18: ...before attempting to start the power source If an electric motor is used to drive the pump re move V belts couplings or otherwise disconnect the pump from the motor before checking motor rotation Oper...

Страница 19: ...STOPPING Never halt the flow of liquid suddenly If the liquid being pumped is stopped abruptly damaging shock waves can be transmitted to the pump and piping system Close all connecting valves slowly...

Страница 20: ...in bearing temperatures is a warning that the bearings are at the point of failing to operate properly Make certain that the bearing lubricant is of the proper viscosity and at the cor rect level see...

Страница 21: ...grpumps com warranty or call U S 419 755 1280 International 1 419 755 1352 For Canadian Warranty Information Please Visit www grcanada com warranty or call 519 631 2870 THE GORMAN RUPP COMPANY MANSFI...

Отзывы: