![GORMAN-RUPP PUMPS 16A2-F3L Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/gorman-rupp-pumps/16a2-f3l/16a2-f3l_installation-operation-and-maintenance-manual-with-parts-list_2246808039.webp)
10 SERIES
OM−00698
MAINTENANCE & REPAIR
PAGE E − 16
NOTE
The white reflector in the sight gauge must be posi-
tioned horizontally to provide proper drainage.
Under normal conditions, drain the intermediate
once each year and refill with approximately 7−1/2
ounces (22 ml) of clean oil. Change the oil more fre-
quently if the pump is operated continuously or in-
stalled in an environment with rapid temperature
change.
Monitor the condition of the bearing lubri-
cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.
Engine
Consult the literature supplied with the power
source, or contact your local Deutz engine repre-
sentative.