type of the device: 1-channel ANT-KO1/1 set
the set contains: a 1-channel RSU KO1 receiver and a 3-button PUK 303 remote control
TECHNICAL PARAMETERS OF THE RECEIVER
•
class: C
•
type of receiving module: superreaction
•
sensitivity: -100 dBm
•
frequency: 433,92 MHz
•
radio transmission: KeeLoq hopping code by Microchip
Technology
•
memory capacity: 14
•
voltage supply:
- nominal: 12 V DC
- allowable: 10-15 V DC
•
power consumption:
- static: 17 mA
- maximal: 40 mA
•
capacity:
- relay output: 1A/ 30 V DC
- S transistor output: 0,5A/ 12 V DC
- sabotage output: 50mA/ 12 V DC
•
number of relays: 1
•
relay's operating mode: mono or bistable
•
time scope for the mono mode: ~1s-4min20s
•
operating temperature range (°C): 0 to +40
•
dimensions (mm): 48*68*26
•
cooperation: any GE sender
•
operating range (m)*: 100-500
•
colour: white
* the range depends on the type of the sender
TECHNICAL PARAMETERS OF THE REMOTE CONTROL
•
class: C
•
frequency: 433,92 MHz
•
transmission: coded (KeeLoq hopping code by Microchip
Technology)
•
number of buttons: 3
•
sending power: <5mW
•
power supply: 1 battery 9V/GF22
•
dimensions (mm): 123*35*20
•
colour: black
•
cooperation: any GE receiver
•
operating range (m):
with superreactive receiver: 300
with heterodyne receiver: 600
The operating range of the set is 300 metres. It concerns the open space (without any obstacles, when the
receiver and the remote control can “see each other”). If there are any obstacles between the receiver and the
sender, one must assume that the range would be reduced: for wood and plaster it would be 5-20% lower, for
bricks 20-40% lower, and for reinforced concrete 40-80% lower.
If there are many obstacles we advise to configure the sets using the receivers of the SH class, to use
retransmitters or stronger remote controls. If there are metal obstacles, using the radio systems is not
recommended.
The device meets the requirements of the directives EMC 89/ 336/ EEC and
RTTE 1999/ 5/ EC.
Gorke Electronic Sp. z o.o.