OPERATION AND MAINTENANCE

The water heater is ready for use once it has been connected to water and other sources of 

heating.

The usual main sources of heating of water for sanitary use are central heating or solar 

power; in this case any regulation of water heating is performed in the heating system.

Electric heater type R may be additionally installed on the flange 

180mm, or electric heater type 

SH to the connecting bushing G 6/4, which are used for additional heating of water:

-  If you need higher temperature of water than assured by other heating sources,

-  If due to seasonal or other conditions there are no main heating sources.

In case of exposure to sub-zero temperatures, the water should be thoroughly drained from 

the heater before the onset of freezing conditions.

Once that is done, open the hot water tap on one of the mixer taps connected to the water 

heater. The water from the water heater drains by way of the drain valve on the inlet pipe. 

External parts of the water heater may be cleaned with a mild detergent solution. Do not use 

solvents and abrasive cleaners.

Regular preventive maintenance inspections ensure faultless performance and long life of 

your heater. The first of these inspections should be carried out by an authorised maintenance

service provider about two years from the date of installation in order to inspect the wear 

of  the  corrosion  protection  anode  and  to  remove  any  limestone  as  required.  Build-up  of 

limestone is a product of quality, quantity and temperature of water flowing through the water

heater. While inspecting the heater, the maintenance service provider will also recommend 

the date of the next inspection.

Wear of the corrosion protection anode is carried out visually. Replacement is required when 

the inspection reveals that the anode diameter has been substantially reduced or worn all 

the way to the steel core.

Tank warranty is subject to regular inspections of the protective anode. 

In the event of the water heater breaking down, you are kindly requested to contact 

the authorised maintenance service provider located closest to you. Please do not 

attempt to repair the unit yourself.

GB

Содержание KGV 200-1

Страница 1: ...KGV 200 300 ...

Страница 2: ... following heating sources via heat exchanger central heating hot water system solar power heating pump Electric heater type R may be additionally installed on the flange 180mm or electric heater type SH to the connecting bushing G 6 4 INSTALLATION The heater should be installed in a dry room that is not subject to freezing conditions preferably in the vicinity of other sources of heating e g boil...

Страница 3: ...ank height Insert the feeler into the channel and fix it with the enclosed rubber tap Recommended position h1 h2 of the feeler is marked on the drawing If the feeler is mounted higher than recommended the thermostat will react too fast the operating time of the circular pump will be shorter and the difference between the temperature in the hot water tank and heating media after the thermostat switc...

Страница 4: ...tem this can result in dripping from the outflow of the safety valve The drip can be piped into the drain by installing a catching unit just below the safety valve The drainpipe fitted under the safety valve outflow must be piped down in a straight vertical line and located in an environment free from the onset of freezing conditions In case the existing plumbing does not enable you to pipe the dripp...

Страница 5: ...various sources of heating are shown in the drawings below Connection to solar panels Connection to the central heating hot water system 1 Water heater 2 Central heating hot water system 3 Solar panel 4 Differential thermostat with sensors T1 T2 T3 T4 5 Bypass pump 6 Expansion tank 7 Non return valve 8 Safety valve 9 Air relief valve 10 Fill drain valve 11 Reduction valve 12 Drain valve 13 Stop va...

Страница 6: ...ts of the water heater may be cleaned with a mild detergent solution Do not use solvents and abrasive cleaners Regular preventive maintenance inspections ensure faultless performance and long life of your heater The first of these inspections should be carried out by an authorised maintenance service provider about two years from the date of installation in order to inspect the wear of the corrosio...

Страница 7: ...06 2008 766383 Gorenje Tiki d o o SI 1521 Ljubljana Magistrova 1 Slovenija Telefon 386 1 5005 600 Fax 386 1 5005 702 382 012 722 ...

Отзывы: