INSTALLATION INSTRUCTIONS
CAUTION
•
Connect the indoor unit first, then the outdoor unit.
•
Do not allow the piping to let out from the back of the indoor unit.
.
•
Be careful not to let the drain hose slack.
•
Insulate both of the auxiliary pipes.
•
Be sure that the drain hose is located at the lowest side of the bundle. Locating
at the upper side can cause drain pan to overflow inside the unit.
•
Never intercross nor intertwist the power wire with any other wiring.
•
Run the drain hose sloped downward to drain out the condensed water smoothly
.
•
For wrapping the pipes and cables use reinforced tape.
Outdoor unit installation
Precautions
•
Install the outdoor unit on a rigid base to prevent increasing noise level and
vibration.
•
In the case that the installation place is exposed to strong wind such as a seaside,
make sure the fan operating properly. If there are problems put the unit lengthwise
along the wall or use a barrier
(picture 12).
•
Especially in windy area, install the unit in a way to protect unit from the wind.
•
If need suspending installation, the installation bracket should accord with technique
requirement in the installation bracket diagram. The installation wall should be solid
brick, concrete or the same intensity construction,
or actions to reinforce, damping supporting should be taken. The connection
between bracket and wall, bracket and the air conditioner should be
firm, stable and reliable.