Gas connection
Safety precautions
The appliance must be connected in accordance with the
standing ragulations, and it may be used only in well ventilated
rooms. Before any attempt to connect the appliance read
carefully the instructions!
These instructions are only valid if country symbol appears on
the appliance. If the symbol does not appear on the appliance, it
is necessary to refer to the technical instructions which will
provide the necessary instructions concerning modifications of
the appliance to the conditions of use of the country.
Before installation and connection check if the local connection
specifications (type and pressure of gas) correspond to the
specifications of the appliance.
The technical specifications of the appliance are indicated upon
the rating plate.
This appliance is not connected to a combustion products
evacuation device. It shall be installed and connected in
accordance with current instalation regulations. Particular
attention shall be given to the relevant requirements regarding
ventilation.
The use of a gas cooking appliance results in the production of
heat, moisture and products of combustion in the room in which
it is installed. Ensure that the kitchen is well ventilated
especially when the appliance is in use.
Keep natural ventilation holes open or install a mechanical
ventilation device (mechanical extractor hood).
Prolonged intensive use of the appliance may call for additional
ventilation, for example opening of the window, or more
effective ventilation, for example increasing the level of
mechanical ventilation where present.
Connection
Connect the appliance in accordance with the regulations of the
local gas supplier.
Gas cooker is equipped with the ISO7-1 R
½” gas connection on
the right side.
During connection hold the elbow R 1/2 to prevent it from turning.
Use metal or non metal gaskets for connection packing. Metal
gaskets may be used only once. Thickness of non-metal gaskets
can be deformed up to 25% maximally.
Appliance connected to a gas connection hose attested
The hose may not touch the bottom side of the appliance, or the
back and the top of the oven.
If the kitchen element below the hob has an integrated oven, it
must be fitted with the cooling fan and the connection hose must
entirely be made of metal (for example flexible stainless steel gas
connection hose). Connection hose must not touch the top oven
panel or the hob bottom.
Check sealing of all joints and couplings after
connection.
14
Caution:
Содержание GC340AC-TG
Страница 1: ...HK Instructions for use mounting and connection BUILT IN GAS HOB GCW340AC TG GC340AC TG For Town Gas...
Страница 17: ...17 WE RESERVE THE RIGHT TO ALTER THE SPECIFICATIONS WITH NO INFLUENCE ON THE OPERATION OF THE APPLIANCE...
Страница 18: ...VD DOMINO GC340AC TG GCW340AC TG GB HK 2012 06 05 SAP 336788...