IMPORTANT INSTALLATION

SPECIFICATIONS

The installer should note that the appliance that side

walls should be no higher than the hot plate itself.

Furthermore, the rear wall, the surfaces surrounding

and adjacent to the appliance must be able to withstand

an overtemperature of  65K.

The adhesive used to stick the plastic laminate to the

cabinet must be able to withstand a temperature of not

less than 150° C otherwise the laminate could come

unstuck.

The appliance must be installed in compliance with the

provisions in force.

This appliance is not connected to a device able to

dispose of the combustion fumes. It must therefore be

connected in compliance with the above mentioned

installation standards. Particular care should be paid to

the following provisions governing ventilation and

aeration.

5) ROOM VENTILATION

It is essential to ensure that the room in which the

appliance is installed is permanently ventilated in order

to allow the appliance itself to operate correctly. the

necessary amount of air is that required for regular gas

combustion and ventilation of the relative room, the

volume of which must not be less than 20 m

3

. Air must

naturally flow through permanent openings in the walls

of the room in question. These openings must vent the

fumes outdoors and their section must be at least 

100 cm

2  

(see fig. 3). Construction of the openings must

ensure that the openings themselves may never be

blocked. Indirect ventilation by air drawn from an

adjacent room is also permitted, in strict compliance

with the provisions in force. 

CAUTION: if the burners of the cooking top are

without safety thermocouple, the ventilation outlet

must have a minimum 200 cm² section.

6) LOCATION AND AERATION

Gas cooking appliances must always dispose of their

combustion fumes through hoods. These must be

connected to flues, chimneys or straight outside. If it is

not possible to install a hood, an electric fan can be

installed on a window or on a wall facing outside 

(see fig. 4). This must be activated at the same time as the

appliance (see fig. 5), so long as the specifications in the

provisions in force are strictly complied with. 

INSTALLATION

39

Содержание 235459

Страница 1: ...SVETO FO R KG COD 04057RUUCGBGO 04057RU 19 02 2009 G640X 235459 G650X 235460 G640X 235459 G650X 235460...

Страница 2: ...SVETO FO R KG 2 1 Moc 3500 3700 W 2 Moc 2300 2500 W 3 Moc 1400 W 4 Moc 1750 W 6 Moc 1000 W 7 2 8 2 10 1 11 2 12 3 13 4 15 6 16 wok G640X 235459 G650X 235460...

Страница 3: ...SVETO FO R KG 3 1 p 1 1 1 1 5 1 2 1 p 1 1 2 W 3500 3700 24 26 2300 2500 20 22 1400 16 18 1750 16 18 1000 10 14...

Страница 4: ...SVETO FO R KG 4 3 4 5 3 4 5 5 6...

Страница 5: ...SVETO FO R KG 5 2 6 6 6 6...

Страница 6: ...SVETO FO R KG 6 3 7 760 8 3 4 E 9 S F 10 60 7 7 8 9 10 A B C D E 4 553 473 63 5 63 5 95...

Страница 7: ...SVETO FO R KG 7 65K 150 5 20 100 3 200 6 4 5...

Страница 8: ...SVETO FO R KG 8 7 o 2 o EN 10226 o 2 c o L 1 2 EN 10226 90 396 93 68...

Страница 9: ...SVETO FO R KG 9 8 11 11 L N 65K m 3 65K EN 60 335 1 EN 60 335 2 6 u EN 60 335 2 102 2004 108 CE 2006 95 11...

Страница 10: ...SVETO FO R KG 9 1 12 D 12 G20 G30 10 12...

Страница 11: ...3700 2 G 30 G 20 G 20 30 13 20 182 244 238 78 zE 128 zA 120 zA 800 800 800 2500 2300 2500 3 G 30 G 20 G 20 30 13 20 102 148 133 60 zE 105 zA 89 zA 550 550 550 1400 1400 1400 4 G 30 G 20 G 20 30 13 20...

Страница 12: ...SVETO FO R KG 11 V 14 15 16 17 D 18 19 17 18 19 14 15 16 12...

Страница 13: ...SVETO FO R KG 13 20 20 8 H05 RR F 3 0 75...

Страница 14: ...FO R KG 14 4 II2H3 G30 30 mbar G20 13 mbar G20 20 mbar Qn 6 1kW G20 13mbar 6 65kW G20 20mbar 220 230 V 50 Hz 4 II2H3 G30 30 mbar G20 13 mbar G20 20 mbar Qn 8 2kW G20 13mbar 8 95kW G20 20mbar 220 230 V...

Страница 15: ...SVETO FO R KG 15...

Страница 16: ...SVETO FO R KG 16 LLLLLLLLLLLLLLLL LLLLLLLLLLLLLLL LLLLLLLLL 2002 96 CE waste electrical and electronic equipment WEEE...

Страница 17: ...SVETO FO R KG I i G640X 235459 G650X 235460 I i G640X 235459 G650X 235460 COD 04057RUUCGBGO 04057UC 19 02 2009...

Страница 18: ...SVETO FO R KG 18 G640X 235459 G650X 235460 1 Moc 3500 3700 W 2 Moc 2300 2500 W 3 Moc 1400 W 4 Moc 1750 W 6 Moc 1000 W 7 2 8 2 10 1 11 2 12 3 13 4 15 6 16 wok...

Страница 19: ...SVETO FO R KG 1 p 1 1 1 1 5 OFF 2 1 1 1 2 19 W 3500 3700 24 26 2300 2500 20 22 1400 16 18 1750 16 18 1000 10 14...

Страница 20: ...SVETO FO R KG 20 3 4 5 3 4 5 5 6...

Страница 21: ...SVETO FO R KG 21 2 6 6 6 i 6...

Страница 22: ...SVETO FO R KG 22 3 L 7 8 3 4 9 S F 10 i i i i i i i i 60 i 7 7 8 9 10 A B C D E 4 553 473 63 5 63 5 95...

Страница 23: ...SVETO FO R KG 23 65K 150 5 20 100 3 200 6 4 5...

Страница 24: ...SVETO FO R KG 24 7 o EN 10226 o o 2 o o 2 1 2 EN 10226 90 396 93 68...

Страница 25: ...SVETO FO R KG 25 8 11 11 L N 65K i ic i 3 65 EN 60 335 1 EN 60 335 2 6 ma EN 60 335 2 102 2 0 0 4 1 0 8 C E 2006 95 11...

Страница 26: ...SVETO FO R KG 26 9 1 12 D 12 G20 G30 12...

Страница 27: ...30 G 20 G 20 30 13 20 182 244 238 78 zE 128 zA 120 zA 800 800 800 2500 2300 2500 3 b G 30 G 20 G 20 30 13 20 102 148 133 60 zE 105 zA 89 zA 550 550 550 1400 1400 1400 4 G 30 G 20 G 20 30 13 20 127 14...

Страница 28: ...SVETO FO R KG 28 11 V 14 15 16 17 D 18 19 17 18 19 14 15 16...

Страница 29: ...SVETO FO R KG 29 20 8 H05 RR F 3 0 75 2 H 20...

Страница 30: ...R KG 30 4 II2H3 G30 30 mbar G20 13 mbar G20 20 mbar Qn 6 1 kW G20 13mbar 6 65 kW G20 20mbar 220 230 V 50 Hz 4 II2H3 G30 30 mbar G20 13 mbar G20 20 mbar Qn 8 2 kW G20 13mbar 8 95 kW G20 20mbar 220 230...

Страница 31: ...SVETO FO R KG 31...

Страница 32: ...SVETO FO R KG 32 LLLLLLLLLLLLL LLLLLLLLLLLL LLLLL 2002 96 EG waste electrical and electronic equipment WEEE...

Страница 33: ...SVETO FO R KG Instructions for the installation and advice for the maintenance G640X 235459 G650X 235460 Instructions Manual G640X 235459 G650X 235460 COD 04057RUUCGBGO 04057GB 19 02 2009...

Страница 34: ...of 1000 W 7 Enamelled steel pan support 2F right 8 Enamelled steel pan support 2F left 10 Burner n 1 control knob 11 Burner n 2 control knob 12 Burner n 3 control knob 13 Burner n 4 control knob 15 B...

Страница 35: ...t it again HOW TO USE THE BURNERS Bear in mind the following indications in order to achieve maximum efficiency with the least possible gas consumption use adequate pans for each burner consult the fo...

Страница 36: ...air vents clear fig 3 and by activating the mechanical aeration device suction hood or electric fan fig 4 and fig 5 Intensive and lengthy use of the appliance may require additional ventilation This c...

Страница 37: ...salted water lemon or tomato juice from remaining in contact with the enamelled surfaces for long periods of time WARNINGS comply with the following instructions before remounting the parts check that...

Страница 38: ...pliance belongs to class 3 and is therefore subject to all the provisions established by the provisions governing such appliances 4 FIXING THE HOT PLATE The hot plate has a special seal which prevents...

Страница 39: ...to operate correctly the necessary amount of air is that required for regular gas combustion and ventilation of the relative room the volume of which must not be less than 20 m3 Air must naturally flo...

Страница 40: ...pressure governor conforming to the provisions in force and must be connected o with a copper pipe The joints of this pipe must consist of unions with mechanical seals o With seamless flexible stainle...

Страница 41: ...se reductions adapters of shunts for connection since these could create false contacts and lead to dangerous overheating The outlet must be accessible after the built in When the appliance is connect...

Страница 42: ...e fig 1 Remove knob fig 12 of the tap which is simply pressed on to its rod Insert a small screwdriver D into hole C fig 12 and turn the throttle screw to the right or left until the burner flame has...

Страница 43: ...nominal rate table also lists the heat inputs of the burners the diameter of the injectors and the working pressures of the various types of gas BURNER ARRANGEMENT ON THE HOT PLATE CONVERSIONS TABLE F...

Страница 44: ...s Greasing the taps see fig 18 19 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions remove the tap Clean the cone and its housing using a c...

Страница 45: ...ction 3 x 0 75 mm2 TYPE OF TYPE OF SINGLE PHASE HOT PLATE CABLE POWER SUPPLY ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors...

Страница 46: ...ural 6 1 kW G20 13 mbar 6 65 kW G20 20 mbar VOLTAGE 220 230 V FREQUENCY 50 Hz TECHNICAL DATA ON THE DATA LABEL 4 BURNERS with ultra rapid left burner CATEGORY II2H3 G30 Butane 30 mbar G20 Natural 13 m...

Страница 47: ...SVETO FO R KG TECHNICAL DATA FOR THE APPLIANCE GAS REGULATION 47...

Страница 48: ...r possession Please also note that genuine spare parts are only available from our After Sales Service Centers and authorized retail outlets The above data are printed on the data label put on the inf...

Отзывы: