GB 36
INSTALLATION
Connection for hobs with 5 cooking zones:
• 3 phases with 1 zero connection (3 1N, 400 V~ / 50 Hz):
▷
The voltage between the phases and the zero is 230 V~. The
voltage between the phases is 400 V~. Fit a connecting bridge
between connecting points 4-5. The groups must have fuses of at
least 16 A (3x). The core diameter of the connecting cable must
be at least 2.5 mm
2
.
The bridges on the connecting block can be used to create the required
connections, as indicated in these illustrations.
Fix the cable with a pull relief and close the cover.
Connection point, wall-mounting socket and plug must be accessible at
all times.