GORE TE Connectivity CeeLok FAS-T Скачать руководство пользователя страница 4

4

Pin

Wire

1

Green

2

Green/White

3

Brown

4

Brown/White

5

Blue

6

Blue/White

7

Orange

8

Orange/White

14. Using an insertion tool, insert each primary into the connector 

according to the following table (Figures 23–24):

Figure 23: Diagram of 

pin positions    

Figure 24: Inserting primaries into the connector

15. Slide the braid back toward the plug. Using the braid brush or 

pick, brush the braid until it fans over the knurled part of the 
connector (Figure 25).

Figure 25: Brushing the braid

Figure 27: Marking the cable 

Figure 28: Slitting the cable jacket 

Figure 26: Returning the outer jacket 

16. With your fingers or needle-nose pliers, push the outer jacket 

as close as possible to the connector, and trim excess jacket 
material (Figure 26).

Terminating the Receptacle Connector (Termination B) 

1. Slide the other piece of the TAT onto the cable. 
2. Measure and mark the cable 1.0 inch from the receptacle end 

of the cable (Figure 27).

3. Using a scalpel or scissors, slit the cable’s jacket from its edge 

to the mark (Figure 28).

GORE

®

 Aerospace

Ethernet Cables

Termination Instructions —  

TE Connectivity

®

 CeeLok FAS-T

®

Connector System

Содержание TE Connectivity CeeLok FAS-T

Страница 1: ...ined tubing TAT 4 Cut the cable to the desired assembly length minus 1 9 centimeters cm to allow for length of the connectors i e 1 3 cm for the plug connector and 0 6 cm for the receptacle connector...

Страница 2: ...3 Using a scalpel or scissors slit the cable s jacket from its edge to the mark Figure 12 4 Using needle nose pliers gently pull the outer jacket down the cable until you have exposed approximately 2...

Страница 3: ...tear the foil along the tape edge Figure 17 10 Mark each primary 0 8 inch from the end of the cable Figure 18 11 Use 22 gauge hand strippers to strip the outer layer of dielectric off from the edge t...

Страница 4: ...re 25 Brushing the braid Figure 27 Marking the cable Figure 28 Slitting the cable jacket Figure 26 Returning the outer jacket 16 With your fingers or needle nose pliers push the outer jacket as close...

Страница 5: ...sible 7 Markeach pair 0 9 inch from the end of the cable Figure 31 8 Cut a 0 5 inch piece of copper or polyimide tape for each pair of the cable Wrap a piece around each pair at the mark made in Step...

Страница 6: ...acts into the M22520 2 01 and select setting 3 To prevent stray wire strands during crimping strip and crimp one primary at a time Figure 38 14 Using an insertion tool insert each primary into the con...

Страница 7: ...e 45 Trimming excess braid on plug Figure 47 Taping the plug Figure 44 Attaching Band It to receptacle Figure 50 Shrinking tubing on receptacle Figure 46 Trimming excess braid on receptacle Figure 48...

Страница 8: ...V15 GORE Aerospace Ethernet Cables TE Connectivity and CeeLok FAS X are trademarks of the TE Connectivity LTD family of companies BAND IT Tie Dex and Tie Dex II are registered trademarks of BAND IT ID...

Отзывы: