4
Pin
Wire
1
Green
2
Green/White
3
Brown
4
Brown/White
5
Blue
6
Blue/White
7
Orange
8
Orange/White
14. Using an insertion tool, insert each primary into the connector
according to the following table (Figures 23–24):
Figure 23: Diagram of
pin positions
Figure 24: Inserting primaries into the connector
15. Slide the braid back toward the plug. Using the braid brush or
pick, brush the braid until it fans over the knurled part of the
connector (Figure 25).
Figure 25: Brushing the braid
Figure 27: Marking the cable
Figure 28: Slitting the cable jacket
Figure 26: Returning the outer jacket
16. With your fingers or needle-nose pliers, push the outer jacket
as close as possible to the connector, and trim excess jacket
material (Figure 26).
Terminating the Receptacle Connector (Termination B)
1. Slide the other piece of the TAT onto the cable.
2. Measure and mark the cable 1.0 inch from the receptacle end
of the cable (Figure 27).
3. Using a scalpel or scissors, slit the cable’s jacket from its edge
to the mark (Figure 28).
GORE
®
Aerospace
Ethernet Cables
Termination Instructions —
TE Connectivity
®
CeeLok FAS-T
®