1
Termination
Instructions
GORE
®
Aerospace
Ethernet Cables
TE Connectivity
®
CeeLok FAS-T
®
Connector System
The following procedures are based on Gore’s best practices
for terminating GORE
®
Aerospace Ethernet Cables with the TE
Connectivity
®
CeeLok FAS-T
®
Connector System for both plug and
receptacle versions. These procedures should be used as a guide
in conjunction with current connector manufacturing instructions.
Preparing the Cable and Parts
1. Gather the tools and materials required for assembly and
termination (Figures 1–9).
2. Verify that you have the correct parts for your assembly by
checking the part numbers for the connectors and the GORE
®
Aerospace Ethernet Cables listed on drawing DDA0238.
3. Cut two 1.0-inch pieces of 0.50-inch thin-walled adhesive-
lined tubing (TAT).
4. Cut the cable to the desired assembly length minus 1.9
centimeters (cm) to allow for length of the connectors (i.e.,
1.3 cm for the plug connector and 0.6 cm for the receptacle
connector).
5. Print any labels required by the end-user, and slide the center
label onto the cable.
6. To identify the end for the receptacle connector, place a piece
of tape on the end in which the pairs rotate clockwise in order
of green
orange
blue
brown (Figure 10).
Figure 10: Pairs configuration
at receptacle end
1
Gore recommends using copper foil tape instead of polyimide tape during termination
procedures because copper tape is easier to use and improves signal integrity.
Figure 1: Needle nose pliers, scalpel, tweezer scissors, and hand strippers
Figure 3: Crimpers (M22520/2-01)
Figure 5: Clamp tool (Tie-Dex
®
II)
Figure 7: Braid brush
Figure 8: Insertion/extraction tool (DHK 696)
Figure 9: Probe/pick
Figure 6: Copper foil tape
1
(3M-3313)
Figure 2: Cutters
Figure 4: Positioner (K1850)