Termination 

Instructions

GORE

®

 Aerospace

Ethernet Cables

TE Connectivity

®

 CeeLok FAS-T

®

 Connector System

The following procedures are based on Gore’s best practices 
for terminating GORE

®

 Aerospace Ethernet Cables with the TE 

Connectivity

®

 CeeLok FAS-T

®

 Connector System for both plug and 

receptacle versions. These procedures should be used as a guide 
in conjunction with current connector manufacturing instructions.

Preparing the Cable and Parts

1. Gather the tools and materials required for assembly and 

termination (Figures 1–9).

2. Verify that you have the correct parts for your assembly by 

checking the part numbers for the connectors and the GORE

®

 

Aerospace Ethernet Cables listed on drawing DDA0238.

3. Cut two 1.0-inch pieces of 0.50-inch thin-walled adhesive-

lined tubing (TAT).

4. Cut the cable to the desired assembly length minus 1.9 

centimeters (cm) to allow for length of the connectors (i.e., 
1.3 cm for the plug connector and 0.6 cm for the receptacle 
connector). 

5. Print any labels required by the end-user, and slide the center 

label onto the cable.

6. To identify the end for the receptacle connector, place a piece 

of tape on the end in which the pairs rotate clockwise in order 
of green 

 orange 

 blue 

 brown (Figure 10).

Figure 10: Pairs configuration 

at receptacle end

Gore recommends using copper foil tape instead of polyimide tape during termination 
procedures because copper tape is easier to use and improves signal integrity.

Figure 1: Needle nose pliers, scalpel, tweezer scissors, and hand strippers

Figure 3: Crimpers (M22520/2-01)

Figure 5: Clamp tool (Tie-Dex

®

 II)       

Figure 7: Braid brush 

Figure 8: Insertion/extraction tool (DHK 696)

Figure 9: Probe/pick

Figure 6: Copper foil tape

1

 

(3M-3313)

Figure  2:  Cutters            

Figure 4: Positioner (K1850)

Содержание TE Connectivity CeeLok FAS-T

Страница 1: ...ined tubing TAT 4 Cut the cable to the desired assembly length minus 1 9 centimeters cm to allow for length of the connectors i e 1 3 cm for the plug connector and 0 6 cm for the receptacle connector...

Страница 2: ...3 Using a scalpel or scissors slit the cable s jacket from its edge to the mark Figure 12 4 Using needle nose pliers gently pull the outer jacket down the cable until you have exposed approximately 2...

Страница 3: ...tear the foil along the tape edge Figure 17 10 Mark each primary 0 8 inch from the end of the cable Figure 18 11 Use 22 gauge hand strippers to strip the outer layer of dielectric off from the edge t...

Страница 4: ...re 25 Brushing the braid Figure 27 Marking the cable Figure 28 Slitting the cable jacket Figure 26 Returning the outer jacket 16 With your fingers or needle nose pliers push the outer jacket as close...

Страница 5: ...sible 7 Markeach pair 0 9 inch from the end of the cable Figure 31 8 Cut a 0 5 inch piece of copper or polyimide tape for each pair of the cable Wrap a piece around each pair at the mark made in Step...

Страница 6: ...acts into the M22520 2 01 and select setting 3 To prevent stray wire strands during crimping strip and crimp one primary at a time Figure 38 14 Using an insertion tool insert each primary into the con...

Страница 7: ...e 45 Trimming excess braid on plug Figure 47 Taping the plug Figure 44 Attaching Band It to receptacle Figure 50 Shrinking tubing on receptacle Figure 46 Trimming excess braid on receptacle Figure 48...

Страница 8: ...V15 GORE Aerospace Ethernet Cables TE Connectivity and CeeLok FAS X are trademarks of the TE Connectivity LTD family of companies BAND IT Tie Dex and Tie Dex II are registered trademarks of BAND IT ID...

Отзывы: