Desktop Transceiver SFX-TAP4_2/C, V0.1, Technical Description
21
Since in the example one SFX-TAP4 is connected with the SCANFLEX controller, four sub
registers appear in the register
TAP
, one per TAP. This allows TAP related definition of the
values.
Moving the mouse cursor to an entry area and waiting 1 sec, the allowed value
range is displayed. Wrong Parameters are displayed in red and automatic
limitation to minimum / maximum are set for those.
Parameters shown in figure 13 are default. They are chosen for each new
configuration. All parameters max be changed by the user.
For more information about configuration refer to SYSTEM CASCON documentation [1].
5.2.1 TIC Type
Using the scrollbar
Type
(see figure 13), you can select the TIC type.
Type 01
must be selected
for operation.
For de-activation, select
None
. It removes a TAP from the configuration without deleting it from
the SFX-TAPx. For this purpose, it is switched off and no other values can be defined.
5.2.2 Output Voltage
The output voltage can be defined within following limits:
Parameter
Min.
[V]
Max.
[V]
Resolution
[V]
Default
[V]
Accuracy
[V]
Output Voltage
1.8
4.5
0.05
3.3
0.1
The voltage entry is set in
DH
(see figure 13). The applicable output driver is given by the
defined voltage. More information can be found in chapter 4.8.
5.2.3 Input Voltage
The Input voltage is applicable within following limits:
Parameter
Min.
[V]
Max.
[V]
Resolution
[V]
Default
[V]
Accuracy
[V]
Input voltage
0.0
3.0
0.05
1.0
0.1
The voltage entry is set in
EH
(see figure 13). It is a HIGH threshold. Voltages above will be
understood as logic High, otherwise Low.
Содержание SFX-TAP2/C
Страница 4: ......