Block Diagram
Technical Parameters
6
.
1
Technical Parameters
Integrated
Integrated
Integrated
(optional)
Integrated
Integrated
Category
Ⅱ
/
(optional
)
280V ~910Vdc
0
MC4 SUNCLIX
*
17
18
Utility Loss
1.Grid is not connected.
2.Check grid connection cables.
3.Check grid usability.
Fac Failure
1. The PV Inverter will automatically restart within 5 minutes if the grid returns to
normal.
2. Make sure grid frequency is in conformity with the specification.
3. Contact local service office for help if the problem still exists.
Inverter
failure
1. Check whether the PV open voltage is higher or too close to the maximum input
voltage.
2. If the problem still exists when PV voltage is less than the maximum input voltage,
contact local service office for help.
1. The internal temperature is higher than normal value specified.
2. Reduce ambient temperature.
3. Move the inverter to a cool place.
4. If the problem still exists, contact local service office for help.
1.Turn
off DC switch of the inverter.
2.Wait
till
inverter
LCD
unlighted.
3.Turn
on DC switch and make sure it connected.
4.If the problem still exists, contact local service office for help.
PV Over Voltage
Over Temperature
Relay-Check Failure
DC Injection High
EEPROM R/W Failure
SCI Failure
SPI Failure
DC
Bus High
GFCI Failure
IFan Fault
EFan Fault
AFan Fault
1.Turn
off DC switch, take off DC connector, check inverter module voltage.
2.Plug in DC connector, and turn
on DC switch.
(1)
3.If voltage is lower than 250V , please check configuration of invert module.
(1)
4.If voltage is higher than 250V , please contact local office.
(1)
Notice: 1. At the place that marked in the chart, GW10K
/
12K
/
15K
/
17K
/
20K
/
25K
-
DT is 250V, GW4000
/
5000
/
6000
-
DT is 180v.
2. When sunlight is insufficient, the PV Inverter may continuously start up and shut down automatically due to insufficient
power generated by the PV panel.
No display
System
Fault
Ground I Failure
1. The ground current is too high.
2. Unplug the inputs from the PV generator and check the peripheral AC system.
3. When the problem is cleared, reconnect the PV panel and check the Inverter status.
4. Contact local service office for help if the problem still exists.
Vac Failure
1. The PV Inverter will automatically restart within 5 minutes if the grid returns to
normal.
2. Make sure grid voltage is in conformity with the specification.
3. Contact local service office for help if the problem still exists.
Display
Possible actions
Isolation Failure
1
.
Check the impedance between PV (+) & PV (-) and make sure the
inverter is earthed.
The impedance value must be greater than 2M.
2
.
Contact local service office for help if the problem still exists.
Model
DC input Data
Max. DC power(W)
Max. DC voltage (V)
MPPT voltage range (V)
Starting voltage (V)
Max. DC current (A)
DC overcurrent protection(A)
No. of DC connectors
No. of MPPTs
DC overvoltage category
DC connector
PV input operating voltage range
Isc PV(absolute maximum)
AC Output Data
Norminal AC power(W)
Max. AC power(W)
Max. AC current(A)
AC overcurrent protection(A)
Norminal AC output
AC output range
THDi
Power factor
Grid connection
AC overvoltage category
Current (inrush)
Maximum output fault current
Efficiency
Max. efficiency
Euro efficiency
MPPT adaptation efficiency
Protection
Residual current monitoring unit
Anti-islanding protection
DC switch
AC over current protection
Insulation monitoring
10200
1000
260~850
250
22/11
33
4
2
10000
10000
17
42
21
.
25
98.0%
>97.5%
99.9%
12300
1000
260~850
250
22/11
33
4
2
12000
12000
19
42
23
.
75
98.0%
>97.5%
99.9%
20500
1000
260~850
250
22/22
33
6
20000
20000
30
60
37
.
5
98.2%
>97.5%
99.9%
17500
1000
260~850
250
22/22
33
6
17000
17000
25
54
31
.
25
98.2%
>97.5%
99.9%
15400
1000
260~850
250
22/22
33
6
15000
15000
25
54
31
.
25
98.2%
>97.5%
99.9%
25800
1000
260~850
250
27/27
38
6
25000
25000
37
72
46
.
25
98.2%
>97.5%
99.9%
50/60Hz; 400Vac
45~55Hz/55~65Hz; 310~480Vac
<1.5%
0.9 leading~0.9 lagging
3W/N/PE
Category
Ⅲ
45A 75us
0
2 (can parallel)
5 Troubleshooting
If the Inverter is not able to work properly, please refer to the following instructions before contact your local service.
Should any problems arise, the red (FAULT) LED indicator on the front panel lights up and the LCD screen will display relevant
information. Please refer to the following table for a list of error message and associated solutions.
9200
1000
260~850
250
22/11
33
4
2
9000
9000
15
42
18
.
75
98.0%
>97.5%
99.9%
GW25K-DT
GW09K-DT
GW12K-DT GW15K-DT GW17K-DT
GW20K-DT
GW10K-DT
Max.inverter backfeed current to the array
26.4A / 13.2A
26.4A/26.4A
32A/32A
Maximum output overcurrent protection