Goodwe GW009K-DT Скачать руководство пользователя страница 1

DT/Smart DT SERIES USER MANUAL

3

5

0

-0

0

0

1

4

-0

5

SOLAR INVERTER

Official

 

Website

Global Service Hotline

:+

86

 

4009

-

281

-

333 

GoodWe

Europe

) 

Mürwikerstr. 59
24943 Flensburg Germany
T: 

+

49

 

461

 

5897

 

0235

[email protected]
www.goodwe.de

GoodWe

China

 

No.189 Kunlunshan Rd.,SND,
Suzhou, 215163, China
T: +86 512 6239 6771 
[email protected]
www.goodwe.com.cn

GoodWe

Australia

) 

74 Tarana Avenue,
Glenroy VIC 3046, Australia
T: +61 3 9972 9938 
[email protected]
www.goodwe.de

GoodWe

UK

) 

93 Caversham Place
Sutton Coldfield B73 6HW
T:

 +

44 12 1238 0053 

[email protected]
www.goodwe.com

.

cn

GoodWe 

Netherlands

) 

Zevenwouden 194 

3524 CX Utrecht, the Netherlands 
T: 

+

31

 

6

 

1988

 

6498

  +

31

 

6

 

1784

 

0429

 

[email protected]
www.goodwe.com

.

cn

Company Wechat

Содержание GW009K-DT

Страница 1: ...D Suzhou 215163 China T 86 512 6239 6771 service goodwe com cn www goodwe com cn GoodWe Australia 74 Tarana Avenue Glenroy VIC 3046 Australia T 61 3 9972 9938 australia goodwe com cn www goodwe de Goo...

Страница 2: ...tificates 3 1 Mounting Instruction 3 2 Overview and Packaging 3 3 Inverter Installation 3 4 Electrical Connection 4 1 LED Lights 4 2 User Interface and Controls 4 3 Error Code 4 4 WiFi Reset WiFi Relo...

Страница 3: ...should not touch replace any of the components except for the DC AC connectors GOODWE will not bear any consequences caused by unauthorized actions which will lead to potential injury to people and da...

Страница 4: ...ts The installation method and mounting location must be suitable for the inverter s weight and dimensions Mount on a solid surface Select a well ventilated place sheltered from direct sun radiation P...

Страница 5: ...the impedance of neutral wire and earth wire less than 10 ohm 4 Disconnect the breaker or fuse between the inverter and the utility 5 Connect the inverter to the grid as follows Installation instructi...

Страница 6: ...connector There are two types of DC connectors SUNCLIX and MC4 series Please refer to Figure 3 4 2 1 Installation instruction of SUNCLIX connectors please refer to Figure 3 4 2 2 SUNCLIX Series MC4 Se...

Страница 7: ...terproof kit to inverter Fasten the screw cap of the cable gland Cables 3 4 5 WiFi Communication The WiFi communication function is only applied to WiFi models the detailed configuration instruction c...

Страница 8: ...User Interface and Controls LED lights in Yellow Green Red correspondently refer to POWER RUN FAULT Yellow Light on indicates the inverter is electrified To WiFi model inverters If the Power light fla...

Страница 9: ...ar mode display annual power generation for recent 10 years Take day mode for example 72kWh means the maximum power generation of recent 16 days The unit on the left corner sometimes turns to MWh from...

Страница 10: ...Long press ENTER in the model type interface there will be set safety interface Press Down or Up to choose the safety you need and then long press ENTER the chosen safety will be set If there is no EX...

Страница 11: ...s Vac Failure 1 The PV Inverter will automatically restart within 5 minutes if the grid returns to normal 2 Make sure grid voltage is in conformity with the specification 3 Contact local service offic...

Страница 12: ...ng Ambient temperature range Relative humidity Moisture location category Max operating altitude Protection degree Environment category External environment pollution degree Topology Night power consu...

Страница 13: ...ble tools and other plug connected equipment Category III applies to fixed equipment downstream of and including the main distribution board Examples are switchgear and other equipment in an industria...

Страница 14: ...Fans DT series inverter is fitted with two fans on its left side The fan intakes and handle covers should be cleaned yearly with a vacuum cleaner For more thorough cleaning completely remove the fans...

Страница 15: ...I RES_13E 7 2 Checking the DC Switch DC switch does not require any maintenance It is recommended though not compulsory to Check the DC switch regularly Activate the DC switch 10 times in a row once a...

Отзывы: