Goodwe DNS Скачать руководство пользователя страница 12

11

Indicator

Status

Description

Steady Yellow

Power on

Single Yellow Blinking

WiFi module reset or restore

Double Yellow Blinking Not connected to the router
Quadra Yellow Blinking Not connected to the monitoring website
Yellow Blinking

RS485 communication normal

Off

The WiFi module is restoring factory settings.

Steady Green

The power grid is working normally and 

on-grid.

Off

Off grid

Steady Red

System error

Off

No error

Faulty

Operating

Power

China

Select 

Country/Region

China

Long Press 2s

Short Press

1. Select the right safety country accordingly.

06       Power On

1.  If it displays Select Country/Region on the LCD when you power on the 

equipment for the first time, you can set the safety country via the LCD or  

SolarGo APP. For more details, refer to Commissioning part. For other settings, 

please refer to the user manual.

2.  Observe the indicators to check the inverter status. If any fault exists, please 

refer to the Troubleshooting part in the user manual.

DNS Series

User Manual

07       Commissioning

2. Wait for 20s, the inverter will automatically set the safety country and back to the standby page.

Commissioning via LCD

PV 

PV 

DC Switch

AC Switch

Grid

Inverter

OFF

ON

DC Switch

1

2

3

Содержание DNS

Страница 1: ...DNS Quick Installation Guide Ver 1 2 2021 08 16...

Страница 2: ...ranty details please visit http www goodwe com DC Side 1 Ensure the component frames and the bracket system are securely grounded 2 Connect the DC cables using the delivered DC connectors and terminal...

Страница 3: ...Potential risks exist Wear proper PPE before any operations Read through the guide before any operations Delayed discharge Wait until the components are totally discharged after power off High temper...

Страница 4: ...Introduction 1 PV Input Terminal 2 DC Switch 3 WiFi 4G LAN GPRS Communication Module Port or RS485 Communication Cable Port 4 DRED CT Remote Shut down Communication Cable Port 5 AC Output Terminal 6...

Страница 5: ...odule 1 Number of expansion bolts screws and terminals are various depending on the different inverters The actual accessories may differ Communication module types WiFi 4G LAN GPRS etc The actual mod...

Страница 6: ...05 15 6 5 1 2 3 M5 1 2 2N m 4 Avoid the water pipes and cables buried in the wall when drilling holes Angle Requirements Installing the Inverter...

Страница 7: ...ypes of AC connector will be delivered randomly The actual connector may differ L L1 1 2 mm L1 S 4mm2 M5 1 2 2N m 1 2 3 1 2 5 6 2 3 1 8 10mm 10 15mm 8 10mm 2 5mm2 S 4mm2 3 4 Connecting the PE Cable Co...

Страница 8: ...07 1 2 4 7 8 2 5 1 3 6 10 12mm 10 15mm 10 12mm 2 5mm2 S 4mm2 3 4 3 5 1 4 6 2 Click M3 0 8N m AC OUTPUT L N PE 3 4 5 7 3 1 6 8 4 2 Click PE L N M3 0 8N m AC OUTPUT Type Two AC Connector...

Страница 9: ...08 Click 7 8mm 7 8mm 1 2 3 4 1 1 2 3 4 1 1 2 3 4 5 2 2 Click Click 2 5mm2 S 4mm2 4 5mm 600V PV1 PV2 PV1 PV2 Connecting the DC Cable...

Страница 10: ...3 3 3 3 4 4 4 4 4 1 4 DRED CT 6 5mm 25mm 1 DRED CT 3 DRED CT 1 2 CT 1 CT 2 1 M3 0 8N m 4 2 4 4 4 4 2 CT DRED 3 3 3 3 4 1 4 Connecting the DRED Remote Shutdown Communication Cable Optional Connecting...

Страница 11: ...ble DC input cable AC output cable and communication cable are connected correctly and securely 3 Cable ties are routed properly and evenly and no burrs 4 Unused ports and terminals are sealed 5 The v...

Страница 12: ...ss 2s Short Press 1 Select the right safety country accordingly 06 Power On 1 If it displays Select Country Region on the LCD when you power on the equipment for the first time you can set the safety...

Страница 13: ...s based on Android system 3 Log in using the initial password for the first time and change the password as soon as possible To ensure account security you are advised to change the password periodica...

Страница 14: ...JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO LTD No 90 Zijin Rd New District Suzhou 215011 China www goodwe com service goodwe com SEMS Portal App GOODWE O cial Website SolarGo App 340 00595 00...

Отзывы: