![GoodPRO FR7 Jakub Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/goodpro/fr7-jakub/fr7-jakub_instructions-for-use_2244204002.webp)
Instructions for use
protective garment against heat risks
Good
PRO
FR7
Jakub
PPE - category III
Tests:
Maintenance:
Before washing zip up the garment, fasten all Velcro fasteners and take off the suspenders. We recommend washing at 40
°C with
gentle machine wash, light spin, pH max.9. Use ordinary liquid detergents without any bleaching agents. Prewash excessively soiled
garments. Rinse thoroughly and tumble dry at max spin speed 800 rpm. We recommend free drying in a warm room or drying in a
dryer in 2 cycles (max 2x20min) at a lower temperature-
max 60°C.
Do not iron directly onto reflective tapes. HIGHER WASHING AND
DRYING TEMPERATURES CAUSE FASTER WEAR OUT OF THE GARMENT!
Storage:
Store in dry and well-ventilated areas away from direct sunlight and UV rays. Protect from any damage.
Notes:
Keep the garment clean otherwise it can lead to the degradation of its properties. Check after every use. To ensure the greatest
possible protection do not make any alternations to the garment and/or its design. The garment keeps its protective features only in
the environment with standard volume of oxygen. To maintain the required level of protection, every two-part suits must be worn
complete. Check and maintain the garment regularly.
Manufacturer does not warrant nor shall manufacturer be liable, or in any way
responsible, for damages to a product caused by abuse (including, but not limited to, improper use, lack of reasonable care and
maintenance and/or any alteration). In case of any questions, please contact the manufacturer
You will find a Declaration of Conformity at www.goodpro.cz
Notified Body 1023 performed EU Type-Examination of the suit
FR7
Jakub
.
EN ISO 11612:2015
A1 B1 C1 F1
EN ISO 11611:2016
class 1/A1
EN 1149-5:2019
EN 13034+A1:2009
Test according EN ISO 11612:2015
Requirements
Evaluation
Heat resistance -
180 °C
ISO 17493
met
Limited flame spread
EN ISO 15025 , method A
A1
Convection heat
HTI
24
4
–
10 s
B1
Radiant heat
RHTI
24
7
–
20 s
C1
Contact heat
–
heat resistance 250 °C
5
–
10 s
F1
Test according EN ISO 11611:2016
Requirements
Evaluation
Limited flame spread
EN ISO 15025 , method A
A1
Small hot metal drops
15 drops / 40 K
met
Radiant heat
RHTI
24
> 7 s
met
Vertical resistance
> 10
5
Ω
met
Test according EN 1149-5:2019
Requirements
Evaluation
Method 2
–
Half decay time
T
50
< 4 , S > 0,2
met
Test according EN 13034+A1:2009
Requirements
Evaluation
Resistance against repellency
H
2
SO
4
30%
NaOH 10%
R > 95 %
class 3
Resistance against penetration
H
2
SO
4
30%
NaOH 10%
P < 1 %
class 3