STEP
CONNECT OUTPUT
OF TEST
EQUIPMENT
CONNECT INPUT
OF TEST
EQUIPMENT
SIGNAL
MARRER
FREQUENCY
SET RADIO
DIAL TO
ADJUST
ADJUST FOR
1
FM IF SWEEP
GENESCOPE TO
TIP4
AND
GND
FM IF SWEEP
GENESCOPE TO
GROUND AND
TIP3
10.7 MHz
LOW-END
FREQUENCY
T5/T1
FOR MAX
SYMMETRICAL
AND LINDAR"S"
CURVE AT 10.7MHz
2
3
4
90 MHz
90 MHz
5
106 MHz
106 MHz
6
L4
VC1-B
L2
VC1-A
MAX PEAX AT
CORRESPONDTNG
MARKER
FREQUENCY
REPEAT STEP 4 AND 5
FM ALIGNMENT PROCEDURE
SET BAND SWITCH TO RADIO MANUAL. VOLUME AT MINTMUM.BAND SW. IM"FM"POSITION.
FM RF SWEEP
GENESCOPE TO
TIP4
AND
GND
FM RF SWEEP
GENESCOPE TO
GROUND AND
TIP1/AND GND
87.5
MHz
108.5
MHz
LOW-END
PREQUENCY
HIGH-END
FREQYENCY
Содержание GCR300
Страница 1: ...Service Manual GCR300 GCR300 Service Manual GCR300...
Страница 2: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......