Goodman TSTATG4271GT Скачать руководство пользователя страница 48

Assemble tools: Flat blade screwdriver, wire cutters and wire
strippers.

Carefully unpack the thermostat.  Save the screws, any brack-
ets, and instructions.

Make sure your Heater/Air Conditioner is working properly 
before beginning installation of the thermostat.

Turn off the power to the Heating/Air Conditioning system at 
the main fuse panel.  Most residential systems have a separate 
breaker for disconnecting power to the furnace.

To install the thermostat properly, please follow these step by
step instructions.  If you are unsure about any of these steps, 
call a qualified technician for assistance.

Remove the cover of the old thermostat.  If it does not come off 
easily, check for screws.

Loosen the screws holding the thermostat base or subbase to the
wall and lift away.

Keep the old thermostat for reference purposes, until your new
thermostat is functioning properly.

Disconnect the wires from the old thermostat.  Tape the ends
of the wires as you disconnect them, and mark them with the
letter of the terminal for easy reconnection to the new thermo-
stat.

Remove & Replace the Old Thermostat

Installation Instructions

Page 42

Содержание TSTATG4271GT

Страница 1: ...per Outdoor Sensor Ready for ease of use SD card required for set up SD card not included Installation Instructions Air Conditioning Heating HighResolution FullColor TouchScreenDisplay DigitalThermost...

Страница 2: ...2 this device must accept any interference received including interference that may cause undesired operation Follow the Installation Instructions before proceeding Set the thermostat mode to OFF prio...

Страница 3: ...that the space should drop to before heating is turned on without regard to deadband Icon The word or symbol that appears on the thermostat display Mode The current operating condition of the thermos...

Страница 4: ...n button Setting the time Setting the date Daylight Savings setup The Main Menu Buttons Schedule View My Schedule Edit My Schedule Time Period Schedule On Off Smart Fan Smart Fan Minimum Runtime Start...

Страница 5: ...f Security Setpoint Limits Mode Restrictions Auto Screenlock Backdrop On Off 20 Sound Options 26 27 27 28 33 31 31 31 31 31 32 Information View Runtime Graphs Who To Call For Service 32 32 Settings Av...

Страница 6: ...6 50 56 49 Explanation Of the Thermostat Dip Switches The TouchScreen Thermostat Backplate Wire Connections Remove Replace the Old Thermostat Sample Wiring Diagrams Troubleshooting Index Warranty Inst...

Страница 7: ...Buttons Main Menu Screen Scrolling Buttons Back Button Menu Buttons Indicates Options Available Backlit Color Touchscreen Display Outdoor Temperature If optional sensor is installed With high low temp...

Страница 8: ...ANERS THAT CONTAIN SOLVENTS DO NOT SPRAY ANYTHING DIRECTLY ONTO THE THERMOSTAT Pencils pens and other sharp objects should never be used on your TouchScreen thermostat these may damage your touchscree...

Страница 9: ...mode will adjust only the heat or cool setpoints Cool Setpoint Warmer Button Fan Cooler Button Heat Setpoint Press to adjust temperature or The Heat or Cool Setpoint is the temperature the room has t...

Страница 10: ...ime Use AM PM ON Set Time Date Set Current Date Daylight Savings Setup Quick Start Set Time Date Daylight Savings Time OFF Start Schedule Starts On Day Month Stop Schedule Ends On Day Month 2nd Sun Ma...

Страница 11: ...12 00 AM hr hr min min Press and to set the current time Press when finished Press then to scroll down Press Use AM PM ON Use AM PM OFF For 12 hour AM PM clock For 24 hour clock Choose Press when fini...

Страница 12: ...20 21 22 23 24 31 30 29 28 27 26 25 1 2 3 4 5 6 7 Press Set Time Date Press BACK Daylight Savings Time OFF Daylight Savings Time ON Start Schedule Starts On Day Month Stop Schedule 2nd Sun March Ends...

Страница 13: ...Page 7 The Main Menu Buttons Information Time Period Schedule OFF The Main Menu Buttons Schedule View My Schedule Edit My Schedule Schedule...

Страница 14: ...each time period is adjustable The stop time for each time period is the start time for the next period Press to turn Schedule On or Off Press a day of the week to view its settings This may be repea...

Страница 15: ...Continued Adjust Mode Start Time and Heat and Cool Setpoints to desired settings Save Edit Next The Main Menu Buttons The Time Period may also be Enabled or Disabled Un check the Enabled box for Time...

Страница 16: ...For Service View Runtime Graphs The Main Menu Buttons Information Smart Fan OFF Smart Fan Min Runtime The Main Menu Buttons Smart Fan Who To Call For Service View Runtime Graphs Start Stop Times Days...

Страница 17: ...ess to turn fan schedule on or off Set the minimum number of minutes the fan will run from the top of each hour Set runtime to 60 minutes to be on continuously from Start Time to Stop time 5 60 mins S...

Страница 18: ...creensaver OFF Screensaver Setup Screensaver Turn On Delay Change Image After Show Clock OFF Screensaver Type Screensaver Home Screen Info OFF View Runtime Graphs Screensaver Preview Slideshow Digital...

Страница 19: ...iew your screensaver operation before returning to the Home Screen After the preview press anywhere on the screen to return to the sub menu Screensaver Screensaver Setup The Screensaver allows you to...

Страница 20: ...Max Filter Runtime Reset Air Filter Alert Reset UV Lamp Alert Alerts Set Edit Reminders Service Information UV Lamp Reminder OFF Max UV Lamp Runtime The Main Menu Buttons Alerts 300 hrs Set Max Filter...

Страница 21: ...t current service alerts Set service alert runtimes and turn reminders on or off Alerts will appear on the bottom bar of the Home Screen Press to view and reset current alerts View and reset current s...

Страница 22: ...Page 16 Screen Cleaning Touch Calibration Active Brightness Night Dimmer Display Maintenance Auto Night Dimmer OFF Set Idle Brightness Set Dimmer Schedule The Main Menu Buttons Display Idle Brightness...

Страница 23: ...is active for 3 minutes after last touch it then goes Idle You may dim the brightness of the TouchScreen screen at night The screen can be set to dim automatically at night Dimming the display can pr...

Страница 24: ...d calibrate the TouchScreen Screen Cleaning Mode disables the touch feature for 15 seconds so the screen may be cleaned without altering any settings Under normal circumstances the TouchScreen should...

Страница 25: ...es Custom Wallpaper Heat Cool Indicator OFF Taskbar Red White OFF Room Temp Red Blue OFF Mode Status Red Blue OFF Preferences Heat Cool Indicator Backdrop OFF Sound Options Beep OFF Beep Sound The Mai...

Страница 26: ...AM it will return to a daytime scene You may choose your own background image by selecting a photo that you have uploaded from an SD memory card Sound Options Beep ON Beep Sound Beep 1 Beep OFF Turn...

Страница 27: ...Page 21 Vacation Mode OFF Schedule Start Date Start Time Return Date Return Time Vacation Mode Heat Setpoint Cool Setpoint Mode Setpoints OFF Auto Heat Cool The Main Menu Buttons Vacation...

Страница 28: ...dule Vacation Vacation Mode must be OFF to change Schedule Mode and Setpoint settings Start Date Tue Sep 07 2010 Start Time 9 00 AM The Main Menu Buttons Vacation Select the day Vacation Mode will sta...

Страница 29: ...s Vacation Continued Select the day Vacation Mode will end Then press Select the time Vacation Mode will end Then press Select the desired Mode and setpoints to be used in Vacation Mode Vacation Mode...

Страница 30: ...reenlock Setpoint Limits Security Mode Restrictions Auto Screenlock OFF Set Passcode Lock After Setpoint Limits OFF Max Heat Setpoint Min Cool Setpoint No Restrictions No Modes Changes The Main Menu B...

Страница 31: ...ttons Security Lock After Auto Screenlock OFF Use keypad to enter and confirm passcode Set Passcode code not set 5 m Auto Screenlock ON NOTE Code must be set before Auto Screenlock can be turned on Pr...

Страница 32: ...Page 26 View Runtime Graphs Information Last 7 Days Cooling Last 7 Days Heating The Main Menu Buttons Information My Thermostat Who To Call For Service Delete Runtime Data...

Страница 33: ...e Graphs Last 7 Days Cooling Last 7 Days Heating Track your system s runtime energy usage Press the information icon to learn more about each graph Press anywhere on the screen to return to the submen...

Страница 34: ...Heat and Cool Heat Only Cool Only Fahrenheit Celsius Heat Cool Stages Compressor Stages Aux Heat Stages English Spanish Espanol French Francais Heat Cool Stages Continued next page Import Settings fr...

Страница 35: ...and 2nd Stage Timer 2nd Stage Turnoff Point 3rd Stage Deadband Deadband Setpoint 3rd Stage Deadband 3rd Stage Timer 3rd Stage Turnoff Point 4th Stage Deadband Deadband Setpoint 4th Stage Deadband 4th...

Страница 36: ...uel On Off Changeover With Outdoor On Off Adjust Balance Point Aux Heat Lockout Enabled Disabled Aux Heat Lockout Temp Calibrate Sensors Thermostat Outdoor Sensor Test Outputs Fan Off Delay Dealer Inf...

Страница 37: ...heating and cooling options are found in this menu Settings Name appears here General Setup Units F Fahrenheit F Celsius C SD Card Import and export files to and from the thermostat See the TouchScree...

Страница 38: ...start of the Morning time period Please allow 4 8 days for Smart Recovery time to adjust When used with a heat pump electric strip heat will be disabled while Smart Recovery is active Language en Engl...

Страница 39: ...Compressor Min OFF Time 5m None 1 minute or 5 minutes At 6 cycles per hour the HVAC unit will only be allowed to energize once every 10 minutes The Cycles Per Hour limit may be overridden and reset b...

Страница 40: ...egrees the room temperature will need to drop to 66 degrees before the heat turns on 3rd Stage Deadband 4th Stage Deadband 1st Stage Deadband 2 1 6 deg F 2nd Stage Deadband 2nd Stage Deadband 2 2nd St...

Страница 41: ...tings The Main Menu Buttons Free Cooling Mechanical Cooling NO Mechanical Cooling YES If you don t have a compressor set Mechanical Cooling to NO Y1 will then be used to control the Free Cooling Dampe...

Страница 42: ...over to fossil fuel 5 60 deg F This feature is for heat pump applications only This will only appear if the GAS EL or HP is set for HP and the GAS or ELEC is set for Gas dip switch dip switch When Dua...

Страница 43: ...ns Installation Settings Continued Test Outputs Calibrate Sensors Thermostat 0 The thermostat sensor may be calibrated 7 to 7 degrees F Outdoor Sensor 0 The outdoor sensor may be calibrated 7 to 7 deg...

Страница 44: ...in Menu Buttons Factory Defaults Press to reset the thermostat back to the factory settings Dealer Information Upgrade Firmware Press to upgrade the thermostat firmware The SD Card must be in the ther...

Страница 45: ...will turn on the fan and auxiliary stages of heat when there is a demand for heat The 1st stage of heating and all stages of cooling will be unavailable To exit Emergency Heat press the Emergency Hea...

Страница 46: ...e your computer to Configure installation settings Upload dealer and service contact information and company logo Update thermostat firmware www goodmanthermostats com thermostats touchscreen Every ti...

Страница 47: ...k on Save to SD When prompted remove the SD card from the SD card reader on your computer Save to SD At the thermostat Press then Settings SD Card Insert the SD card into the SD Card Slot Next press P...

Страница 48: ...ly please follow these step by step instructions If you are unsure about any of these steps call a qualified technician for assistance Remove the cover of the old thermostat If it does not come off ea...

Страница 49: ...is a Heat Pump Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked G or F Fan G Y1 Y or C Cooling Y1 W1 W or H Heating W1 O B Power Rh R M Vr A R C O B...

Страница 50: ...nstructions The TouchScreen Thermostat Backplate Fan relay G 1st stage compressor relay Y1 24 VAC return R 1st stage heat circuit reversing valve W1 O B 2nd stage heat circuit W2 Y2 2nd stage compress...

Страница 51: ...e Fan G terminal in heating mode When GAS is chosen the thermostat will not energize the Fan G terminal in heating When ELEC is chosen the thermostat will energize the fan in heating For some commerci...

Страница 52: ...re 1 Stage Cooling 1 Stage Heat 24VAC Power 24VAC Common 1st Stage Heat 1st Stage Cool Fan Residential Commercial 2 Stage Cooling with 3 stage Gas Heat 8 Wire 2 Stage Cooling 3 Stage Heat 24VAC Power...

Страница 53: ...Reversing Valve 6 Wire 1 Stage Cooling 2 Stage Heat R 24VAC Power C 24VAC Common W1 O B Reversing Valve Y1 1st Stage Compressor Cool or Heat W2 Aux Heat G Fan Residential Commercial Heat Pump with O R...

Страница 54: ...ual Fuel set to On Free Cooling Free Cooling Damper C R G Y1 Y2 W1 O B W2 W3 10K Thermistor Outdoor Sensor GAS EL HP O GAS B ELEC Page 48 1 2 3 ON Free Cooling utilizes the Y1 terminal for the operati...

Страница 55: ...e sure the power is on to the furnace and that you have 24vac between R C SYMPTOM The heating does not attempt to turn on CAUSE The heating setpoint is set too low REMEDY Raise the heating setpoint or...

Страница 56: ...ge deadband see Deadband Minutes of runtime 27 Custom Wallpaper 20 Cycles Per Hour 33 Buttons Back 1 Cooler 1 3 Fan 1 3 Home 1 Mode 1 3 Menu 1 7 Warmer 1 D Dealer Information 27 38 Delay Fan off see F...

Страница 57: ...and electric strip heat see Aux Heat minutes of runtime 27 3rd stage deadband see Deadband 4th stage deadband see Deadband timer 34 turnoff point 34 electric heat pump 36 mode 3 H program see Schedule...

Страница 58: ...5 thermostat settings see Factory Defaults runtime fan filter 15 UV light 15 Reversing Valve 45 47 Runtime resetting see Reset service filter 15 UV light 15 viewing 15 27 S Screen Cleaning 18 Screensa...

Страница 59: ...tage 34 3rd stage to 4th stage 34 Time schedule see Schedule Touch Calibration 18 TouchScreen Assistant 40 U V Upgrade Firmware 38 User Interface Themes 30 UV Light resetting 15 runtime see Runtime se...

Страница 60: ...Page 54 Notes...

Страница 61: ...Page 55 Notes...

Страница 62: ...WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD...

Страница 63: ...Printed on recycled paper P N 88 876 Rev 1 Page 57...