SS-SSZ16
www.goodmanmfg.com
3
P
roduct
S
PecificationS
S
PecificationS
SSZ16
0241A
SSZ16
0361A
SSZ16
0481A
SSZ16
0601A
Capacities and Ratings
Nominal Cooling (BTU/h)
24,000
36,000
48,000
60,000
Nominal Heating (BTU/h)
24,000
36,000
48,000
60,000
Decibels
70
71
72
72
Compressor
RLA
13.4
14.1
19.8
25.6
LRA
58.3
77.0
109.0
118.0
Condenser Fan Motor
Horsepower
1
/
6
1
/
6
1
/
6
1
/
6
FLA
1.10
1.10
1.10
1.00
Refrigeration System
Refrigerant Line Size¹
Liquid Line Size (“O.D.)
⅜”
⅜”
⅜”
⅜”
Suction Line Size (“O.D.)
¾”
⅞”
1⅛”
1⅛”
Refrigerant Connection Size
Liquid Valve Size (“O.D.)
⅜”
⅜”
⅜”
⅜”
Suction Valve Size (“O.D.)
¾”
⅞”
⅞”
⅞”
Valve Connection Type
Sweat
Sweat
Sweat
Sweat
Refrigerant Charge
153
183
278
273
Electrical Data
Volts / Hz / Phase
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
Minimum Circuit Ampacity ²
17.9
18.7
25.9
33
Max. Overcurrent Protection ³
30
30
40
50
Min / Max Volts
197/253
197/253
197/253
197/253
Electrical Conduit Size
½”
or
¾”
½”
or
¾”
½”
or
¾”
½”
or
¾”
Ship Weight (lbs)
282
282
282
296
¹ Tested and rated in accordance with AHRI Standard 210/240
² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final
Charge Procedure.
• Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.