2
www.goodmanmfg.com
SS-GSX14
SS-GSX14
www.goodmanmfg.com
3
Product Specifications
GSX14
0181L*
GSX14
0191K*
GSX14
0241L*
GSX14
0251L*
GSX14
0301K*
GSX14
0311K*
Capacities
Max Cooling (BTU/h)
18,000
18,000
24,000
24,000
30,000
30,000
SEER/EER
14 / 12
14 / 12.2
14 / 12
14 / 12.2
14 / 12.0
14 / 12.2
Decibels
72
71
74
71
74
72
Compressor
RLA
6.0
9.0
7.7
13.5
12.8
12.8
LRA
37.5
47.5
38.0
58.3
64
67.8
Condenser Fan Motor
Hp
1/8
1/8
1/8
1/8
1/6
1/6
FLA
0.7
0.7
0.7
0.7
0.95
0.95
Refrigeration System
Refrigerant Line Size ¹
Liquid Line Size (“O.D.)
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
Suction Line Size (“O.D.)
¾"
¾"
¾"
¾"
¾"
¾"
Refrigerant Connection Size
Liquid Valve Size (“O.D.)
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
Suction Valve Size (“O.D.) ² ³
¾"
¾"
¾"
¾"
¾"
¾"
Valve Type
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Charge
75
68
72
75
80
90
Included piston:
0.051
0.053
0.057
0.057
0.065
0.063
Electrical Data
Voltage-Phase (60 Hz)
208/230-1
208/230-1
208/230-1
208/230-1
208/230-1
208/230-1
Minimum Circuit Ampacity ⁴
8.2
12
10.3
17.6
17.0
17.0
Max. Overcurrent Protection ⁵
15 amps
20 amps
15 amps
30 amps
25 amps
25 amps
Min/Max Volts
197/253
197/253
197/253
197/253
197/253
197/253
Conduit
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
Equipment Weight
126
131
126
136
162
162
Shipping Weight
141
146
141
153
180
180
¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with AHRI Standard 210/240.
For other line-set lengths or sizes, refer to the installation & Operating instructions and/or the long line-set guidelines.
² Installer will need to supply ¾” to ⅞” adapters for suction line connections.
³ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
⁴ Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
⁵ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes
• Always check the S&R plate for electrical data on the unit being installed.
•
Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
Содержание GSX14 0181L