PACKAGE HEAT PUMP SPECIFICATIONS
25
GPH14[24-36]H41A*
EXPANDED PERFORMANCE DATA
MODEL: GPH1424H41A*
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
-5
-10
MBh
28.7
27.1
25.5
23.9
22.8
22.1
20.5
18.9
16.2
15.0
13.8
13.0
12.5
11.2
10.0
8.7
7.4
6.1
DELTA T
31.2
29.6
27.8
26.0
24.8
24.1
22.4
20.6
17.6
16.3
15.0
14.2
13.6
12.2
10.8
9.5
8.1
6.6
KW
1.86
1.82
1.78
1.75
1.73
1.71
1.67
1.63
1.65
1.61
1.58
1.55
1.54
1.50
1.46
1.42
1.38
1.34
AMPS
9.1
8.4
7.9
7.5
7.2
7.1
6.7
6.4
6.2
5.9
5.6
5.5
5.5
5.2
4.9
4.6
4.3
3.9
COP
4.51
4.36
4.19
4.00
3.87
3.78
3.59
3.39
2.87
2.71
2.56
2.45
2.38
2.19
2.00
1.79
1.57
1.32
EER
15.4
14.9
14.3
13.7
13.2
12.9
12.3
11.6
9.8
9.3
8.7
8.4
8.1
7.5
6.8
6.1
5.4
4.5
HI PR
367
352
338
324
316
310
298
286
274
262
251
245
241
232
223
214
206
199
LO PR
142
132
123
113
107
103
95
84
76
68
60
56
54
45
39
33
29
23
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.
MODEL: GPH1430H41A*
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
34.7
32.8
30.9
28.9
27.6
26.7
24.8
22.9
19.2
17.7
16.3
15.4
14.8
13.3
11.8
10.3
8.8
7.2
DELTA T
30.6
29.0
27.3
25.5
24.3
23.6
21.9
20.2
16.9
15.6
14.4
13.6
13.1
11.7
10.4
9.1
7.7
6.3
KW
2.26
2.22
2.17
2.13
2.10
2.08
2.04
1.99
1.98
1.93
1.89
1.86
1.84
1.79
1.75
1.70
1.66
1.61
AMPS
11.0
10.3
9.7
9.1
8.8
8.7
8.2
7.8
7.5
7.2
6.9
6.8
6.7
6.4
6.0
5.7
5.3
4.9
COP
4.48
4.33
4.16
3.97
3.84
3.76
3.56
3.36
2.84
2.68
2.53
2.42
2.36
2.17
1.97
1.77
1.55
1.30
EER
15.3
14.8
14.2
13.6
13.1
12.8
12.2
11.5
9.7
9.2
8.6
8.3
8.1
7.4
6.7
6.0
5.3
4.5
HI PR
374
359
345
330
322
316
304
291
279
267
256
250
245
236
227
218
210
203
LO PR
134
124
117
107
101
97
89
80
72
64
56
52
51
43
37
31
27
21
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.
MODEL: GPH1436H41A*
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
41.5
39.3
37.0
34.6
33.0
32.0
29.7
27.4
26.9
24.8
22.9
21.6
20.8
18.7
16.5
14.4
12.3
10.1
DELTA T
32.0
30.3
28.5
26.7
25.5
24.7
22.9
21.1
20.8
19.2
17.7
16.7
16.1
14.4
12.8
11.1
9.5
7.8
KW
2.74
2.68
2.63
2.57
2.54
2.52
2.47
2.41
2.64
2.58
2.52
2.48
2.46
2.39
2.33
2.27
2.21
2.15
AMPS
13.5
12.6
11.9
11.2
10.9
10.7
10.1
9.7
9.3
8.9
8.5
8.4
8.3
7.9
7.4
7.1
6.6
6.1
COP
4.44
4.29
4.12
3.93
3.80
3.71
3.52
3.32
2.98
2.82
2.66
2.55
2.48
2.28
2.08
1.86
1.63
1.37
EER
15.2
14.6
14.1
13.4
13.0
12.7
12.0
11.4
10.2
9.6
9.1
8.7
8.5
7.8
7.1
6.4
5.6
4.7
HI PR
367
352
338
323
316
310
298
286
274
262
251
245
241
232
223
214
206
199
LO PR
135
125
117
108
102
98
90
80
72
65
57
53
51
43
37
31
27
21
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.
PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1.
As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low
and high side pressures and power will not change.
2.
As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus
3 degrees
of the typical (
Delta T)
value shown.
A properly operating unit should be within plus or minus
7 PSIG
of the
HI PR
shown.
A properly operating unit should be within plus or minus
3 PSIG
of the
LO PR
shown.
A properly operating unit should be within plus or minus
3 Amps
of the typical value shown.