background image

6

www.goodmanmfg.com

SS-GMVC80/GCVC80

SS-GMVC80/GCVC80

www.goodmanmfg.com

7

Airflow Data

MODEL/TEMP RISE RANGE                   

(MID RISE)

GMVC800803B*A* 

30-60 (45)

GMVC800804C*A*        

25-55 (40)

GMVC800805C*A*                  

20-50 (35)

GMVC800805D*A*              

20-50 (35)

GMVC801005C*A*                  

25-55 (40)

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

Recommended cfm for high heat / 

expected temperature rise 

1330

45

1400

42

1700

35

1700

35

1850

40

Lowest recommended cfm for hi heat / 

expected temperature rise

980

60

1090

54

1175

50

1175

50

1350

55

Maximum cfm for hi heat / expected 

temperature rise

1400

42

1760

34

2200

27

2200

27

2200

34

NOTE: Low Heat CFM = High Heat CFM X .7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± 5%           0140F02402-A

MODEL/TEMP RISE RANGE                   

(MID RISE)

GCVC800603BXA*

25-55 (40)

GCVC800603BXA*                          

30-60 (45)

GCVC800805CXA*                  

25-55 (40)

GCVC801005CXA*               

20-50 (35)

GMVC800603B*A*                   

15-45 (30)

GMVC800604B*A*             

20-50 (35)

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

Recommended cfm for high heat / 

expected temperature rise 

1100

40

1325

45

1470

40

2090

35

1400

32

1275

35

Lowest recommended cfm for hi heat / 

expected temperature rise

810

55

990

60

1070

55

1475

50

980

45

890

50

Maximum cfm for hi heat / expected 

temperature rise

1400

32

1400

42

2200

27

2200

34

1400

32

1760

25

NOTE: Low Heat CFM = High Heat CFM X .7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± 5%                0140F02402-A

GCVC800603BXA*, GCVC800803BXA*

GMCV800603B*A*, GMVC800803B*A*

Cooling Speed 

( @ .1” - .8” w.c. ESP)

GMVC800604B*A*

GMVC800804C*A*

Cooling Speed 

( @ .1” - .8” w.c. ESP)

Tons

High-Stage

Low-Stage

CFM

Tons

High-Stage

Low-Stage

CFM

1.5

600

420

2

800

560

2

800

560

2.5

1,000

700

2.5

1,000

700

3

1,200

840

3

1,200

840

4

1,600

1120

MAX

1,400

MAX

1,760

GCVC800805CXA*

GCVC801005CXA*

Cooling Speed ( @ .1” - .8” w.c. ESP)

GMVC800805C*A*, GMVC800805D*A*

GMVC801005C*A*

Cooling Speed 

( @ .1” - .8” w.c. ESP)

Tons

High-Stage

Low-Stage

CFM

Tons

High-Stage

Low-Stage

CFM

2

800

560

2

800

560

3

1,200

840

3

1,200

840

4

1,600

1,120

4

1,600

1,120

5

2,000

1,400

5

2,000

1,400

MAX

2,000

MAX

2,200

All furnaces ship as high speed for cooling.  Installer must adjust blower speed as needed.

For most jobs, about 400 CFM per ton when cooling is desirable.
Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.

Содержание GCVC800603B A Series

Страница 1: ...out the home Quiet two speed induced draft blower California Low NOx emissions compliant models available Can no longer be installed in California s South Coast Air Quality Management District SCAQMD...

Страница 2: ...ation NOx M Upflow Horizontal N Natural Gas C Downflow Horizontal X Low NOx Motor Cabinet Width V Variable Speed ECM ComfortBridge A 14 C 21 E Multi Speed ECM S Single Speed B 17 D 24 Gas Valve Maximu...

Страница 3: ...Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Vent Diameter 4 4 4 4 4 4 4 No of Burners 3 3 4 4 4 4 5 Electrical Data Min Circuit Ampacity 7 75 10 6 7 75 7 75 10 6 10 6...

Страница 4: ...Data Min Circuit Ampacity 7 75 7 75 10 6 10 6 Max Overcurrent Device amps 15 15 15 15 Ship Weight lbs 105 109 125 129 Natural Gas BTU h for altitudes above from 0 to 4 500 above sea level reduce inpu...

Страница 5: ...enclosure where accessibility clearances are greater Refer to the appropriate USA and Canadian codes In the USA the National Fuel Gas Code NFPA 54 ANSI Z223 1 In Canada the Canada National Standard o...

Страница 6: ...B 1 0 3 6 1 1 Approved for line contact in the horizontal position 24 clearance for serviceability recommended Single Wall Vent SW to be used only as a connector Refer to the venting tables outlined i...

Страница 7: ...d cfm forhiheat expected temperature rise 810 55 990 60 1070 55 1475 50 980 45 890 50 Maximum cfm for hi heat expected temperature rise 1400 32 1400 42 2200 27 2200 34 1400 32 1760 25 NOTE Low Heat CF...

Страница 8: ...bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity GMVCContinuousFanSpeeds Model Furnace Maximum CFM Continuous Fan Speed GMVC800603B A 1400 350 1400 GMVC800604B A 17...

Страница 9: ...UT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 8...

Страница 10: ...ge non communicating outdoor units 4 Optional Use the Heating Trim Menu HtF to adjust the heat pump airflow from 10 to 10 2 increments This applies for 2 stage communicating outdoor units and single o...