Cycles Per Hour (Setup Step 14)
The Cycles Per Hour setting may
limit the number of times per hour
your HVAC unit may energize. For
example, at a setting of 6 cycles
per hour the HVAC unit will only be
allowed to energize once every 10
minutes. The Cycles Per Hour limit
may be overridden and reset by
pressing the WARMER or COOLER
buttons on the thermostat. Settings
are No Limit, 2, 3, 4, 5, or 6 cycles
per hour.
Compressor Minimum
Off Minutes (Setup Step 15)
This feature allows the user to
set a minimum off time for the
compressor. Settings are 0 to 5
minutes.
Minimum Heat/Cool Setpoint
Difference (Setup Step 16)
This feature allows the user to set
the minimum gap between Heat
and Cool setpoints in AUTO mode.
Select from 0 to 6 degrees.
Installer Setup
21