SS-DSXC16
www.goodmanmfg.com
3
P
roduct
S
PecificationS
S
peCifiCAtionS
DSXC16
0241AA/B
DSXC16
0241AC
DSXC16
0361AA/B
DSXC16
0361AC
DSXC16
0481B*
DSXC16
0601B*
Cooling Capacity
Nominal Cooling (BTU/h)
24,000
24,000
36,000
36,000
48,000
60,000
Decibels
71
71
70.4/70.9
70.4/70.9
74
75
Compressor
RLA
10.3
11.7
16.7
15.3
21.2
28.8
LRA
52.0
58.0
82.0
83.0
104.0
152.9
Condenser Fan Motor
Horsepower (RPM)
1/6
1/6
1/6
1/6
1/6
1/6
FLA
1.1
1.1
0.9
0.9
1.2
1.0
Refrigeration System
Refrigerant Line Size¹
Liquid Line Size (“O.D.)
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
Suction Line Size (“O.D.)
¾"
¾"
⅞"
⅞"
1⅛"
1⅛"
Refrigerant Connection Size
Liquid Valve Size (“O.D.)
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
Suction Valve Size (“O.D.)
¾"
¾"
¾"
¾"
⅞"
⅞"
Valve Connection Type
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Refrigerant Charge
97
97
107
107
132
197
Electrical Data
Voltage-Hz
208/230-60
208/230-60
208/230-60
208/230-60
208/230-60
208/230-60
Minimum Circuit Ampacity ²
14.0
15.7
21.8
20.0
27.7
37.2
Max. Overcurrent Protection ³
20
20
35
35
45
60
Min / Max Volts
197/253
197/253
197/253
197/253
197/253
197/253
Power Supply
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
Eqipment Weight (lbs)
181
181
184
184
219
279
Ship Weight (lbs)
198
198
202
202
241
301
¹ Tested and rated in accordance with ARI Standard 210/240
² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
• Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECI
-
FIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL.