![Goodman 0603BNA Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/goodman/0603bna/0603bna_technical-manual_2243407009.webp)
BLOWER PERFORMANCE SPECIFICATIONS
9
*MVM971005CNA
Cooling Speed
(@ .1" - .8" w.c. ESP)
*MVM971005CNA
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)
Tap
Adjust
High-Stage
CFM
Low-Stage
CFM
Tap
Adjust
High-Stage
CFM
Rise
(°F)
A
Minus 10%
738
508
A
Minus 10%
1,636
55
Normal
820
564
Normal
1,818
49
Plus 10%
902
620
Plus 10%
2,000
45
B
Minus 10%
1,020
706
C
Minus 10%
1,683
53
Normal
1,133
784
Normal
1,870
48
Plus 10%
1,246
862
Plus 10%
2,057
44
C
Minus 10%
1,318
884
D
Minus 10%
1,719
52
Normal
1,464
982
Normal
1,910
47
Plus 10%
1,610
1,080
Plus 10%
2,101
43
D
Minus 10%
1,562
1,133
D
Minus 10%
1,761
51
Normal
1,736
1,259
Normal
1,957
46
Plus 10%
1,910
1,385
Plus 10%
2,153
42
*MVM971205DNA
Cooling Speed
(@ .1" - .8" w.c. ESP)
*MVM971205DNA
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)
Tap
Adjust
High-Stage
CFM
Low-Stage
CFM
Tap
Adjust
High-Stage
CFM
Rise
(°F)
A
Minus 10%
780
492
A
Minus 10%
1,702
63
Normal
867
547
Normal
1,891
57
Plus 10%
954
602
Plus 10%
2,080
52
B
Minus 10%
1,044
748
C
Minus 10%
1,746
62
Normal
1,160
831
Normal
1,940
56
Plus 10%
1,276
914
Plus 10%
2,134
51
C
Minus 10%
1,320
918
D
Minus 10%
1,771
61
Normal
1,467
1,020
Normal
1,968
55
Plus 10%
1,614
1,122
Plus 10%
2,165
50
D
Minus 10%
1,719
1,150
D
Minus 10%
1,825
59
Normal
1,910
1,278
Normal
2,028
53
Plus 10%
2,101
1,406
Plus 10%
2,231
48
Notes
•
All furnaces ship as high speed for cooling. Installer must adjust blower
speed as needed.
•
For most jobs, about 400 CFM per ton when cooling is desirable.
•
CFM between .5" and .8" w.c. is tabulated for cooling purposes only.