11. 

Maintenance 

For  best  results  and  long  term  operation, regular  maintenance  is  essential.

 

To ensure the cooler delivers fresh and  clean  air, regularly change  the water and  clean the dust filter and  the 
cooling pad.

 

1. 

Remove  the  filter  pad  by  unscrewing  the  4  screws  on  the  rear  of  the  cooler. Then  lift  the  pad  and  pull  out  at  the  bottom 

to release. To replace the pad, slide  up into the slot under the top of the cooler, push in at the bottom; and allow to drop 
into the lower slot.

 

2.  Clean the  pad from the innerside to outside of  pad  (inner side is towards motor). Never use  any  liquid detergent. Never

 

use pressurized water, as it may cause damage to the pad.

 

3. 

Unscrew the drainage lid to let dirty water  flow out, then  clean the water tank thoroughly with a soft  cloth. Wash off dirt 
on the water sensor, water pump and the float valve. Rinse thoroughly.

 

4.  Use  mild soap and  soft  clean  cloth  when cleaning the cooler casing. Do not use  any caustic chemical detergent that may 

cause damage to the surface of the cooler.

 

5. 

To prevent build-up of algae and other biological organisms in the reservoir, regularly add chlorine/bromine tablets as

 

per  tablet  manufacturer  recommendation  for  evaporative  cooler  reservoirs.

 

 

12. 

Trouble shooting 

Problem

 

Possible cause

 

Solution

 

Operating screen stays dark

 

- No power

 

- Main control board failure

 

- Fuse is blown

 

- Panel failure

 

- Check if unit is plugged in

 

- Change control board

 

- Change fuse

 

- Change panel

 

Display is normal but without air

 

flow or the air speed is too low

 

- The fan is jammed

 

- Cooling pad or dust filter is blocked

 

- Fan is distorted

 

- Main control board failure

 

- Check to ensure there is nothing 

preventing free rotation of the fan

 

- Clean the cooling pad and dust filter

 

- Change the fan

 

- Change the main control board

 

Motor does not respond to control 
panel

 

- Main control board failure

 

- Panel failure

 

- Change the main control board

 

- Change panel

 

Water leaking  from drain valve

 

- Drain valve is loose

 

- Dirt in valve

 

- Tighten drain valve nut

 

- Clean drain valve

 

Air  diffuser/swing  function  not

 

working

 

- Synchronous  motor is burned out

 

- Crankshaft is broken

 

- Change synchronous motor

 

- Change  crankshaft

 

Water drops/splashes out of the air

 

diffuser

 

Water pipe has come loose

 

-Check  water  pipe to top of  filter  pad

 

and  reattach  or  tighten  as  necessary

 

NOTE: 

This troubleshooting is for reference purposes  only. If any technical assistance is  needed, please contact your

 

distributor  for  service/repair

 

Содержание HHB30F

Страница 1: ...User Manual EVAPORATIVE AIR COOLER HHB30F...

Страница 2: ...echnical specifications p 4 5 Technical feature p 4 6 Important reminders p 5 7 Key components p 5 8 Operating instructions p 6 9 Key components p 7 10 Remote controller p 7 11 Maintenance p 8 12 Trou...

Страница 3: ...3 1 Declaration of Conformity...

Страница 4: ...chools workshops workers dormitories outdoor teahouse coffee bars restaurants recreation facilities Manufacturing Textile machinery ceramic refined chemical industries metallurgy hardware and leather...

Страница 5: ...indows open to allow fresh air to enter and treated air to exit when cooler is operating 2 Flashing red light on the control panel means water level in reservoir is low 3 Rinse the reservoir with fres...

Страница 6: ...alitied persons in order to avoid a hazard 5 Water Pressure 0 1 Mpa 10 Keypad instruction Comment ON OFF This turns the cooler on or off COOL This activates the cooling function Note that there is a d...

Страница 7: ...7 9 Key components 10 Remote controller...

Страница 8: ...chlorine bromine tablets as per tablet manufacturer recommendation for evaporative cooler reservoirs 12 Trouble shooting Problem Possible cause Solution Operating screen stays dark No power Main contr...

Страница 9: ...e controller Large water tank for extended time between fills No need for compressed air No installation no duct work required Easy to use easy to clean Body is corrosion proof plastic Easy to maintai...

Страница 10: ...e Netherlands Phone 31 0 10 426 14 10 Fax 31 0 10 473 00 11 Email info dryfast nl Website www dryfast nl Dryfast B V Klein Siberi straat 1C 3900 Pelt Belgium Phone 32 0 3 544 83 94 Fax 32 0 3 544 83 9...

Отзывы: