8 Troubleshooting
Function
Status description
Method for restart
LED
Alarm
AC-
output
Input low-
voltage alarm
green on
red off
yes
yes
When the battery is back
to normal voltage, the
alarm automatically stops�
Input low-
voltage
shutdown
green on
red on
yes
no
• Charge the battery�
• Switch off the voltage
converter for 3-5 seconds
• Switch the voltage con-
verter on again�
Input over-
voltage
shutdown
green on
red on
no
no
• Check the battery for
correct voltage or re-
store it�
• Switch off the voltage
converter for 3-5 seconds�
• Switch the voltage con-
verter on again�
Overload
shutdown
green on
red on
no
no
• Reduce the load to the
specified continuous load.
• Switch off the voltage
converter for 3-5 seconds�
• Switch the voltage con-
verter on again�
Over temperature
shutdown
green on
red on
yes
no
• Eliminate the cause of
overheating�
• Switch off voltage con-
verter for ~5 minutes to
cool down�
• Switch the voltage con-
verter on again�
Output short
circuit
green on
red on
no
no
• Eliminate the cause of
the short circuit�
The voltage transformer
then continues to operate
automatically�