15
User manual
6 mm 15 mm
N
L
GND
1
2 3
4 5 6
Fig. 11: Installation
1. Turn off the fuse.
2. Open the connection sleeve by turning it counter-clockwise until
the connection block is released as shown in Fig. 11 - 1/2.
3. Insulate the cables as shown in Fig. 11 - 3.
4. Slide the parts of the connection sleeve shown in Figs. 11 - 4
over the connection cable.
5. Screw the power cables as shown in Fig. 11 - 5 using a screw-
driver.
6. Close the connector by turning it clockwise, as shown in Figure
11
-
6.
7 Settings
Only floodlights with motion sensor:
Fig. 12:
Adjustments (Floodights with motion sensors)
SENS: SENS adjusts the range of the PIR sensor. This is a mini-
mum of 4 m, maximum of 10 m.
TIME: TIME sets the switch-off delay between min. 10 ± 5 s and
10 ± 2 minutes.