![Gomax MA-5288V2 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/gomax/ma-5288v2/ma-5288v2_user-manual_2241870011.webp)
Operation
Procedure
7-Segment LED
Output
Status
Status
+
Output Number (1~8)
+
Take
Ex: Output 4
(Input 2)
1.Press “STATUS” button
-
-
2.Press output number key “4” to select Output 4
4
-
3.Press “TAKE” button
4
2
Save Current Mapping
Save
+
Output Number (1-8 storage site)
+
Take
Ex: Save current
mapping to 5
1.Press “SAVE” button
d
-
2.Press output number key “5” to select the storage site 5
d
5
3.Press “TAKE” button
Preset Mapping
Preset
+
Output Number (1-8 storage site)
+
Take
Ex: Preset saved
mapping from 5
1.Press “PRESET” button
P
-
2.Press output number key “5” to select the storage site 5
P
5
3.Press “TAKE” button
Learn default EDID
Default EDID
+
Output Number
(1-8 default EDID)
+
Input Number
(input 1~8)
+
Take
Ex: Default EDID 2
Input 3
1.Press “DEFAULT EDID” button
E
d
2.Press output number key “2” to select default EDID 2
2
d
3.Press input number key “3” to select Input 3
2
3
4.Press “TAKE” button
0 F
0 (success) F(fail)
Learn EDID Port EDID
Learn
+
Output 8 (EDID Port)
+
Input Number (input 1~8)
+
Take
Ex: Learn EDID Port
Input 3
1.Press “LEARN” button
E
L
2.Press output number key “8” to select EDID Port
8
L
3. Press input number key “3” to select Input 3
8
3
4.Press “TAKE” button
0 F
0 (success) F(fail)
Mute Output
Mute
+
Output Number (1~8)
+
Take
Ex: Mute Output 3
1. Press “MUTE” button
-
0
2. Press output number key “3” to select Output 3
3
0
3.Press “TAKE” button
3
0
Method C: Software Control through RS-232 port / Ethernet port
1. System Requirement
1) OS Information: MS WinXP/7
2) Baud rates: 9600
3) Software size: 3 MB
4) Minimum RAM requirement: 256 MB
9