ADL190 ADL200 User and Installation Manual 9 / 25
Revision 2.00 - 25.10.2019
A typical wiring will look as follows.
PLEASE NOTE THIS IS FOR ILLUSTRATION
ONLY. ALWAYS CONSULT THE MANUALS OF ALL DEVICES CONNECTED
.
Figure 10
Typical AT-1 / IFD / ADLRS232 / ADL190/200 wiring
Multicore cable
attached
to ADLRS232
ADLRS232 Combiner
1 Port 1 VCC
2 Port 1 RS232 IN
3 Port 1 GND
4 Port 1 RS232 OUT
1 Port 2 VCC
2 Port 2 RS232 IN
3 Port 2 GND
4 Port 2 RS232 OUT
ADL190/200
AT-1 Device
RS232 OUT
GND
To 1A ADL190/200 circuit breaker
Aircraft Ground
IFD (GNS/GTN) Device
RS232 IN
RS232 OUT
GND
Please note on the IFD the
RS232 IN and OUT can not be
used from the same port
number! You have to combine
two ports.
GTN/GNS devices work in a
similar way as the IFD but the
RS232 IN will not work.
9600 baud
115200 baud
115200 baud
115200 baud
IN and OUT