2
SAFETY PRECAUTIONS
- Dip switches for setting the address monitor (call code) and end of line.
- Button status led
'Do not disturb' mode - LED fixed/ 'Doctor mode' - LED slow blink.
- Start / stop communication push button.
- Door release push button.
- 7 TFT colour screen
"
.
- User menu.
- Monitor with simple installation (unpolarised 2 wire BUS).
- Capacitive function buttons to access and select menu functions.
- Installer setup.
-
.
Screen and volume settings menu
- Hands-free monitor.
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Do not overtighten the screws on the connector.
- Install the monitor in a dry protected location free from the risk of dripping or splashing water.
-
Always disconnect the power supply
before making modifications to the device.
- The fitting and handling of these devices must be carried out by
authorised personnel.
.
- Before connecting the system to the mains, check the connections between the door panel, power
supply, distributors and monitors.
- The wiring must run at least
40 cm away from any other wiring.
- Always follow the instructions contained in this manual.
.
CHARACTERISTICS
SYSTEM OPERATION
- The ring tone lasts for 40 seconds. Without alerting the visitor, their image appears on the master
monitor during this time.
: the image appears on the monitor (with code
“
apartment 1
”
or monitor with code 16 if the call is in
“
apartment 2
”
) when receiving the call
without the visitor being alerted
House kit application
0
.
- Communication will last for one and a half minutes or until button
is pressed again. When
communication has finished, LEDs
and will turn off and the channel will be freed. If vocal
synthesis is activated, a
“
Communication is finished
”
message will indicate that the call is over.
or
- To establish communication, press button
on any monitor in the apartment. Door panel LED
will turn on. If monitor is the VESTA7
GB2/H with symbol
in front side,
SE
place the hearing aid
at a distance of 20 cm from the monitor to obtain the maximum audio quality during communication
with the door panel.
- To make a call, the visitor must press the button of the apartment; an audible sound indicates that
the call is being made and LED
will turn on. If vocal synthesis is enabled, a
“
Call is in progress
”
message appears to indicate a call is being made. At this moment the apartment's monitor(s)
receives the call. During the call the visitor can correct his call by pressing a push button
corresponding to a different apartment, in which case the original call is cancelled.
If the call is not answered within 40 seconds, LED
will turn off and the channel will be freed.
- Descriptions of the function push buttons can be found on page 3.
- To open the door 1 or 2 press the push button
/
during the call or communication processes:
one press will activate the lock release for five seconds and LED
will also turn on for five seconds.
If vocal synthesis is activated, a
“
Door Opened
”
message will be indicated on the door panel.
*
( )
*
( ) For more information, see the TVESTA7
GB2 user manual (code 50121960)
“
SE
”
.
https://doc.golmar.es/search/manual/50121960
3
DESCRIPTION OF THE MONITOR
Monitor address (code) setup:
*
( )
*
( ) For more information, see the TVESTA7
GB2 user manual (code
“
SE
50121960)
”
.
https://doc.golmar.es/search/manual/50121960
INSTALLATION OF THE MONITOR
1.60m
x
4 30
Screws supplied with
the embedding box
Surface
Embedding box
Location
*
( )
*
( )
1
2
3
ON
E
: 0 + 0+4+0+16 = 20
xample
Switch number
Value when ON:
: 1 2 3 4 5
1 2 4 8 16
Value chart
DIP
4
5
6
The monitor code is the sum of the values of the switches set to ON.
The values of the switches set to ON are shown in the table below.
Dip6:
Sets the end of line. Set to ON in monitors where the video cable
terminates. Remainder set to OFF.
Dip1
Dip5:
to
Set the monitor address (addresses to 3 )
0
1 .
The switches set to OFF have a zero value.
2-apartment kit Monitor code 1 is the last,
:
5
dip 6 of the end of line to ON.
1
( )
f.
End call/communication button.
g.
In standby: Enters menu.
c.
Start / stop communication push button.
b.
Microphone.
d.
Door release push button 1. Standby: Ext light activation
.
/
a.
7
”
TFT colour screen.
e.
Door release push button 2. Standby: 'do not disturb
’
mode, if
the mode is activated, the icon illuminates
. One press
for 3 sec. activates / deactivates the "do not disturb" mode.
During standby: Display door panel image.
In standby intercom function in the apartment.
In auto spy/auto switch-on: Selects other door panel(s),
camera(s) in descending mode and in carousel (if any).
Press for seconds to activate/deactivate the 'doctor mode'
function (function code [9018] must be activated)
6
In auto spy/auto switch-on: Selects other door anel(s),
camera(s) in ascending mode in carousel (if any).
p
&
h.
In standby: enters menu
screen
communication volume settings
. / Video activated:
&
.
k.
Con
fi
guration DIP switch.
In call/communication: selects camera(s) in
ascending mode and in carousel (if any).
In standby:
status LED will blink indicating that a
photo/video is pending viewing, if press access to
"playback" menu.
i.
.
Vertical wiring entry
j.
.
Connector
fi
xings
l.
n
Co nector.
m.
Bus connection terminals.
n.
Communication with hearing aids (Vesta7
GB2/H).
SE
Put the hearing aid selector in mode .
T
Menu entry and user settings button.
Menu push buttons:
On m
: Divert (no function)
enu screen
.
Menu entry and selection button.
On menu screen: shows door panel image.
l
m
j
k
CODE 0
APARTAMENT 1
CODE 0
CODE 15
APARTAMENT 1
1-apartment kit
2-apartment kit
APARTAMENT 2
1
( )
b
c
f
g
a
d
e
1
2
3
ON
DIP
4
5
6
h
i
j
i
On menu screen: Activates outdoor light.
On menu screen: Intercom function between
apartments.
*
( )
Building
n
EN
EN
VESTA7 SE G 2 - V
7 SE GB2/H
B
ESTA
MONITOR
VESTA7 SE G 2 - V
7 SE GB2/H
B
ESTA
MONITOR
( ontin
)
C
ued
VESTA7 SE
VESTA7 SE
VESTA7 SE