![golmar TEKNA-S GTWIN Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/golmar/tekna-s-gtwin/tekna-s-gtwin_quick-manual_2241709003.webp)
ADVANCED PROGRAMMING
Tekna-S Gtwin
Sistemas de comunicación S.A.
Monitor
Code 50120265
TTEKNA S GTWIN EN QG
REV.0319
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis .
Golmar reserves the right to make any modifications without prior notice.
QUICK GUIDE
50124297
GOLMAR S.A.
C/ Silici, 13
08940- Cornellá de Llobregat
SPAIN
I
mportant:
For optional programming, optional connections and more
information, see the TTEKNA S GTWIN manual (code 50120265).
https://doc.golmar.es/search/manual/
0265
5012
5
4
D4L-GTWIN
DISTRIBUTOR
COLUMN
TO THE FOLLOWING DISTRIBUTORS
NC CONTACT =
DOOR CLOSED
LINE~
FA-GTWIN
POWER SUPPLY
Z=ON
*
( )
Z=OFF
Remove the jumper from all of the
distributors except the last.
*
( )
Video door
entry system
Main panel
To configure
the SAV-GTWIN
call
repeater, see the TTEKNA-S GTWIN
manual, p. 16.
2
( )
2
( )
PA
SP
SE+
SE-
Lock release
max 12 Vdc/270 mA.
SE2
LINE
Exterior door
release button
LINE 1
LINE 2
230
0
S+
S-
To
connect
the
FA-Gtwin
power
supply
to
the
filter
and
line
protector, see the TGTWIN SYSTEM
MANUAL, p. 44.
1
( )
SAV-GTWIN
call repeater
1
( )
LINE IN
LINE OUT
CP
S+
S-
LINE OUT
LINE
3
LINE
4
LINE
1
LINE
2
LINE IN
S+
S-
LINE IN
LINE OUT
CP
LINE IN
LINE OUT
CP
S+
S-
LINE IN
LINE OUT
CP
S+
S-
S+
S-
LINE IN
LINE OUT
CP
S+
S-
LINE IN
LINE OUT
CP
LINE OUT
LINE
3
LINE
4
LINE
1
LINE
2
LINE IN
Apartment
front
door call
3
( )
3
( )
To connect the secondary AC lock
release (Golmar), see the TGTWIN
SYSTEM MANUAL, p. 45.
2
1
INT 0
ON
SW2
2
1
INT 0
ON
SW2
MASTER
MONITOR
2
1
INT 0
ON
SW2
2
1
INT 0
ON
SW2
J2
F. Line
ON (Z)
2
1
INT 0
ON
SW2
2
1
INT 0
ON
SW2
2
1
INT 0
ON
SW2
2
1
INT 0
ON
SW2
Important:
For further information about the door panel, sections, distances,
other wiring diagrams, etc., see the TGTWIN SYSTEM MANUAL,
code 50122345).
2345
https://doc.golmar.es/search/manual/5012
Remember:
Button panel up to 122 apartments.
LINE IN
LINE OUT
CP
S+
S-
S+
S-
LINE IN
LINE OUT
CP
WIRING DIAGRAM
O
ne building with 1 column of up to 127 monitors and 1 main video
panel (buttons).
- Exiting programming mode:
To exit
press button
for more than 5 seconds,
'programming mode,'
1 short and 2 long audible tones will confirm this and the status LED will
turn off, indicating that button
can be released.
Continued from previous page
Note:
When exiting programming mode, if 'doctor mode' has been activated, the
monitor's status LED will blink (green), see p.1.
MONITOR SETTINGS
SW1 configuration switch:
DIP switch 1:
Must be OFF.
DIP switches 2 to 8:
To configure the desired code (2 = most
significant bit and 8 = least significant bit).
Below is an example of a site with 22 apartments:
EL60 D
6
C. 00
EL632/GTWIN
C. 02
C. 04
C. 06
C. 05
C. 03
C. 01
1
8
2 3 4 5 6 7
ON
C. 08
C. 10
C. 09
C. 07
1
2
3
ON
4
5
6
C.126
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
Code Monitor
/telephone
EL610D
1 2
4 5 6 7
3
8
ON
C. 12
C. 14
C. 16
C. 18
C. 20
C. 1
1
C. 19
C. 17
C. 15
C. 13
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
SW2 configuration switch:
INT:
Define the internal code of the monitor/telephone in order to set it as master,
slave 1, slave 2 or slave 3 using the SW2 switch with a code from 0 to 3 respectively.
2
1
INT 1
ON
2
1
INT 0
ON
2
1
INT 2
ON
2
1
INT 3
ON
*
( )
Factory setting.
*
( )
SW2
SW1
1 2 3 4 5 6 7 8 9 10
1 2
NOTE: If it is not used,
join the 'SP' terminals with a cable.
J2
F. Line
ON (Z)
J2
F. Line
ON (Z)
J2
F. Line
ON (Z)
J2
F. Line
ON (Z)
J2
F. Line
ON (Z)
J2
F. Line
ON (Z)
J2
F. Line
ON (Z)
MASTER
MONITOR
MASTER
MONITOR
MASTER
MONITOR
MASTER
MONITOR
MASTER
MONITOR
MASTER
MONITOR
MASTER
MONITOR
Apartment
front
door call
Apartment
front
door call
Apartment
front
door call
Apartment
front
door call
Apartment
front
door call
Apartment
front
door call
Apartment
front
door call
D4L-GTWIN
DISTRIBUTOR
Code Monitor
/telephone
www.golmar.es