background image

OPTIONAL CONNECTIONS

SYSTEM OPERATION

13

O

Nothing operates.

w

Check the output transformer voltage between SEC terminals: it should have 12 

to 17Va.c. If not, disconnect the transformer from the installation and 
measure again. If it's correct now, it means there is a short circuit in the 
installation: disconnect the transformer from mains and check the installation.

O

Inappropriate audio level.

w

Adjust the level volumes as shown on page 6. In case of feedback, reduce the 

audio levels until feedback fade out.

O

Door open function no operates.

w

Remember that in systems with several access doors (EL551 sound modules), this 

function is only available during call and communication progresses.

w

Disconnect the lock release from the sound module and short-circuit terminals ' ' 

and 'P': at that moment the output voltage between terminals 'CV' and '~2' (in 
case of EL550 or EL554 sound modules) or between terminals 'CV' (in case of 
EL551 sound module) should be 12Va.c. If it's so check the lock release, its 
wiring and the wiring of the terminal 'P' from the sound module to the 
telephones. If these tests don't solve the problem, replace the sound module.

O

No telephones receive the call or acknowledgement call signal is not reproduced.

w

Check that the push buttons common terminal are correctly connected to the 

'CP' terminal of the sound module.

O

The door panels don't change to busy status.

w

From the moment a call is made in one of the door panels, the voltage between 

' ' and 'CO' terminals should be lower than 3Vd.c. If not, check the continuity 
of the 'CO' wire.

O

Once a communication is finished the system remains on busy status.

w

If the busy status remains for a three minutes period, even if the handset of the 

called telephone is on the craddle, check that all the telephones are 
correctly replaced.

O

The acknowledgement busy signal is not reproduced.

w

When someone tries to make a call during busy status, the light push button 

should change its color and busy signal should be heard at the door panel. If 
the called telephone is not a  T-900 model, and is not correctly replaced or it 

TROUBLESHOOTING HINTS

14

arallel telephones installation.

P

The maximum number of telephones placed
     in the same apartment is three.
     For each telephone placed in parallel
     the section corresponding to the call wire
     must be doubled.

Electronic call.

Buzzer call.

ind.

ind.

0

7

0

7

10

10

10

10

5

5

5

5

3

3

3

3

P1

P1

P1

P1

O

O

O

O
O

To make a call the visitor should press the push button corresponding to the 

apartment he wishes to contact. An acoustic tone will be heard confirming the 
call as the push button is pressed. At this moment the call will be received at the 
telephone in the dwelling.

In systems with several access doors, the other(s) door panel(s) will be automatically 

disconnected, and the light push button will change to red color: if a visitor tries to 
call from other door panel an acoustic tone will be heard confirming the system is 
busy. If the call is not answered in 30 seconds, the system will be freed.

To establish communication pick up the telephone handset. In systems with several 

access doors, the communication will last for one and a half minutes or until the 
handset is replaced. Once the communication has finished the system will be 
freed.

To open the door, press the door release push button at any moment.
In systems with several access doors, the door open function can be operated 

during call and communication progresses: with one press, the door release 

Содержание Stadio Plus T555ML

Страница 1: ...Stadio Plus T555ML rev 0104 Instructions manual Audio door entry system 4 n installation...

Страница 2: ...sound modules and buzzer call in systems with EL554 sound module with acoustic acknowledgement signal a c lock releases activation Up to three telephones in the same apartment In systems with EL551 so...

Страница 3: ...h headers the door panel will open to left To hold the door panel on the embedding box insert the hinges in the embedding box lockers as shown lace the embedding P box Pass the wiring through the hole...

Страница 4: ...ht side of the terminal connector This jumper allows to select between two different call types allowing the user to distinguish which door panel is calling Fix the door panel by using the supplied sc...

Страница 5: ...t it on the craddle nstalling the TF 104 transformer I To install the transformer directly on the wall insert the fixing flanges Drill two holes of 6mm and insert the wallplugs Fix the transformer wit...

Страница 6: ...not necessary the use of a key The lock release can be activated at any moment by using an external push button that must be connected between and P terminals of the sound module This function will a...

Страница 7: ...NH CO CP L1 L2 ind 1 ind 2 ind 3 P CN1 1 2 TF 104 EL 551 Stadio Plus SEC PRI Main CV CV INH 1 2 INSTALLATION DIAGRAM INSTALLATION DIAGRAM The lock release can be activated at any moment by using an ex...

Страница 8: ...status remains for a three minutes period even if the handset of the called telephone is on the craddle check that all the telephones are correctly replaced O The acknowledgement busy signal is not r...