background image

OPTIONAL CONNECTIONS

14

SECTIONS CHART

15

ind.

0

0

10

10

5

5

3

3

P1

P1

xternal lock release activation.

E

ections chart.

S

inking 3xx1 modules.

L

A1

B1

A2

B2

L1 L2

1

1

L1

2

2

L2

L1 L2

EL505

A window

B window

EL551

If the general entrance door panel contains
     3xx1 window modules to show the busy
     status (see pages 2 and 7), connect the
     window circuits as shown.

arallel telephones installation.

P

The maximum number of telephones placed
     in the same apartment is three.
     For each telephone placed in parallel
     the section corresponding to the call wire
     must be doubled.

The lock release can be activated at any moment
     by using an external push button,
     that must be connected between ' 1' y 'CV' terminals
     of the corresponding door panel sound module.
     This function will allows to exit from the building
     being not necessary the use of a key.

~

0, ind, 5,  , 10,  , P, P1, CO 0,25mm²

0,50mm²

0,50mm²

1,00mm²

1,00mm²

2,50mm²

100m.

300m.

–, 3

~1, ~2, CV

For longer distances than the specified contact with your distributor.

Terminal

Distance

CV

CV

INH

~1

~2

All manuals and user guides at all-guides.com

Содержание Stadio Plus T150i

Страница 1: ...609 807 631 golmar golmar es Golmar reserves the right to make any modifications without prior notice for improvement purposes Audio door entry system for residential complexes 4 n installation All m...

Страница 2: ...To obtain the maximum profit of these features and a properly wired installation we kindly recommend you to expend a few minutes of your time to read this manual O O O Do not use excessive force when...

Страница 3: ...dule nternal door panel I description 2xxx grille module 600 closing heads 3xxx push buttons module mbedding box positioning E 1650 1850 1450 The upper part of the door panel should be placed at 1 65m...

Страница 4: ...by screwing the supplied screws DOOR PANEL INSTALLATION ssembly the sound module A Stick the waterproof seals on the upper and lower headers Insert the sound module in the grille module For a proper...

Страница 5: ...cable through the embedding box junctions Don t remove the protection plug of the last cable as prevention against the humidity ush buttons wiring P Before to wire the window module circuits the inde...

Страница 6: ...or This jumper allows to select between two different call types Set the same type of call on all the internal panels and the other type on the general entrance panels This function will allow the use...

Страница 7: ...e press the door release operates during 3 seconds TELEPHONE INSTALLATION escription of the T 900 D telephone a b c d e f g Telephone handset Speaker grille Microphone hole Subjection hole Telephone c...

Страница 8: ...n ind 1b ind 2b ind 3b CV CV INH CO CP L1 L2 P SEC Main CN1 PRI TF 104 EL 551 JP1 Main SEC PRI TF 104 CP CP A1 B1 CO CO A2 B2 V P P 1 2 CN1 EDIFICIO BLOCK A EDIFICIO BLOCK B EL505 GENERAL ENTRANCE A B...

Страница 9: ...ced in the same apartment is three For each telephone placed in parallel the section corresponding to the call wire must be doubled The lock release can be activated at any moment by using an external...

Страница 10: ...that the push buttons common terminal are correctly connected to the CP terminal of the sound module in case of internal door panels or to the corresponding CP terminal of the EL505 circuit in case of...

Отзывы: