INSTALLATION INSTRUCTIONS
SELECT THE BEST LOCATION
1. To prevent vibration and noise, make sure the
unit is installed securely and firmly
2. Install the unit where the sunlight does not
shine directly on the unit.
3. The outside of the cabinet must extend
outward for at least 12" and there should be
no obstacles, such as a fence or wall, within
20" from the back of the cabinet because it will
prevent heat radiation of the condenser.
Restriction of outside air will greatly reduce
the cooling efficiency of the air conditioner.
CAUTION: All side louvers of the cabinet must
remain exposed to the outside of the structure.
WINDOW REQUIREMENTS
1. This unit is designed for installation in
standard double hung windows with actual
opening widths from 27" to 39".
The top and bottom window sash must open
sufficiently to allow a clear vertical opening of
16" from the bottom of the upper sash to the
window stool.
2. Install the unit a little slanted so the back is
slightly lower than the front(about
1
/
2
").
This will force condensed water to flow to the
outside.
3. Install the unit with the bottom about 30"~60"
above the floor level.
;;
;;
About
1
/
2
"
30"~60"
Awning
Cooled air
Fence
Over 20"
Heat
radiation
Interior wall
Stool
16" min
27" to 39"
1
/
2
" to 1
1
/
4
"
Offset
Sill
Exterior
23
5
/
8
" min
(Without frame curtain)
1
2
3
4
8
9
11
7
6
5
10
13
12
NO.
NAME OF PARTS
Q'TY
1
FRAME CURTAIN
2
2
SILL SUPPORT
2
3
BOLT
2
4
NUT
2
5
SCREW(TYPE A)
16
6
SCREW(TYPE B)
3
7
SCREW(TYPE C)
5
8
FOAM-STRIP
1
9
FOAM-PE
1
10
UPPER GUIDE
1
11
FOAM-PE
1
12
FRAME GUIDE
2
13
WINDOW LOCKING BRACKET
1
INSTALLATION KITS CONTENTS