—15—
2.4 REFRIGERATION CYCLE
2.4.1 CONDENSER
1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the brace and the shroud cover.
(Refer to section 2.2.1)
3. Remove 2 screws which fasten the side
cover.(See Fig. 17(b))
4. Remove the 5 or 6 screws which fasten the
condenser.
5. After discharging the refrigerant completely,
unbraze the interconnecting tube at the condenser
connections.
6. Remove the condenser.
7. Re-install the components by referring to notes.
(See Fig. 17)
2.4.2 EVAPORATOR
1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the top cover and the brace.
(Refer to section 2.2.1)
3. Discharge the refrigerant completely.
4. Remove the 3 screws which fasten the evaporator
at the left side and the top side.
5. Move the evaporator sideward carefully and then
unbraze the interconnecting tube at the evaporator
connectors.
6. Remove the evaporator.
7. Re-install the components by referring to notes.
(See Fig. 18)
2.4.3 CAPILLARY TUBE
1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the brace. (Refer to section 2.2.1)
3. After discharging the refrigerant completely,
unbraze the interconnecting tube at the capillary
tube.
4. Remove the capillary tube.
5. Re-install the components by referring to notes.
Figure 17(a)
Figure 17(b)
Figure 18
Discharge the refrigerant system using Freon
TM
Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before
venting the Freon
TM
. Leave the valve in place
after servicing the system.
CAUTION
Содержание LWC243NSAB0 Y5USC18-6A
Страница 34: ... 34 5 2 ELECTOINC CONTROL DEVICE MODEL M1802 ...
Страница 35: ... 35 MODEL M1803R NOTE 1 The unit of undefined resistors is ohm 1 6W 5 2 The unit of undefined capacitors is uF ...
Страница 37: ... 37 5 4 COMPONENTS LOCATION FOR DISPLAY P C B ASM MODEL M1802 MODEL M1803R PWB P NO 6870A90004D 3 6871A2011B ...
Страница 45: ...MEMO 45 ...
Страница 46: ... 46 MEMO ...
Страница 47: ...P No 3828A20140A January 2005 Printed in Korea ...