User manual – Telos 150 Analog Power Amplifier
3
LINE VOLTAGE ADJUSTMENT
An AC line voltage selection is possible on the rear panel. Please choose the setting corre-
sponding to your voltage.
Please check the value of the mains line fuse. This fuse is located in the power cord receptacle.
The lid can be removed with a small screwdriver when the cord is removed.
Use a 8 A slow-blow fuse.
4
CONNECTIONS
Check if volume control is down to zero on the preamplifier.
Connect the analog outputs of your analog preamplifier to the analog inputs of the Telos 150.
Connect the speaker cables to the red and black terminals accessible at the back of the
amplifiers.
You may notice that the ground of the input and the black speaker terminal are of the same
polarity. The amplifier is non-inverting in phase.
Then, connect the power cords to the back of the amplifier and plug it in the nearest wall plug.
Use a 3 lugs grounded plug, for safety reasons. To get the best sound of the amplifier, avoid
any multiple plug or extension cord.
ATTENTION
: On the 220 V position, the
Goldmund Telos 150 amplifier will func-
tion properly for AC voltages between 200 V
and 245 V. On the 110 V position, the AC
line must deliver between 95 V and 125 V.
If your AC line is usually out of these toler-
ances, please consult your local Goldmund
dealer.