background image

When only one amp is used, leave the ranking to 1. 
If you use several amplifiers, rank them from 1 to their number.  
 
When they will be powered ON in Auto-Power mode by receiving a signal, they will 
start in the order of the rank they have, each after the previous one (few 100 millisec 
later), avoiding the power surges to add-up at the breaker level. 
 
To adjust the rank of each amp, when it is powered off, press the right key until the 
ONRank adjustment is displayed. Change the rank by pressing the left key. 
 
Other display 
An input sensitivity adjustment is provided on the back panel of the amplifier. 
To read the attenuation introduced by this adjustment (in dB), press once the right 
front panel key. The attenuation will be displayed for 10 seconds. 
 
When pressed twice, the front panel right key will display on front panel the output 
circuit temperature, again for 10 seconds. 
 
 
 
 
 
6 – SOUND QUALITY OPTIMIZATION 
 
 
- Warm-up sonic effect. 
If the power amplifier has been powered off for some time, the optimum sound 
quality is only reached after several minutes. The critical circuits have to warm up to 
55 degrees Celsius (+131 degrees Fahrenheit). When the amplifier has 
been used recently, the optimum is reached after only 10 to 15 minutes. 
 
 
 
 
- Speaker polarity. 
Even if you have a phase inverter on your preamplifier (as on the GOLDMUND 
MIMESIS 2 or MIMESIS 22), and even if you have carefully selected the proper line 
phase (see in next paragraph), there is a possibility to again increase the sonic 
quality of your speakers by reverting the polarity of the speaker cable amp 
termination. But since the line phase and the speaker polarity interfere to each other, 
you have to experiment carefully all the combinations before picking the right one. 
If your preamp has an absolute phase inverter, this will interfere too. If it has not, 
don't forget the result will depend of the source, most of the record and CD being 
recorded without care for the absolute phase. Be patient… 
 
 
- Main line phase inversion. 
To select the proper phase, you have to select, by trying, one of the two power cord 
position, using a plug adapter. 

Содержание MIMESIS 29.4M MILLENNIUM EDITION

Страница 1: ...GOLDMUND MIMESIS 29 4M MILLENNIUM EDITION POWER AMPLIFIER...

Страница 2: ...er made for professional and domestic uses Please take some time to read this manual It may provide you with useful information to make your pleasure of listening to the Mimesis 29 4M even higher ATTE...

Страница 3: ...of it equipment sensitive to temperature Due to its weight and to maximize the effect of the built in Mechanical Grounding construction the MIMESIS 29 4M is better located on the floor But other very...

Страница 4: ...reasons To get the best sound of the amplifier avoid any multiple plug or extension cord Connect the interconnects between the preamp and each power amp You may either use the RCA female socket or the...

Страница 5: ...ssing it twice you reach the Auto Power Mode adjustment You may now activate the Auto Power Mode On or Off by pressing the left key In Auto Power mode the amp is turned on automatically when receiving...

Страница 6: ...has been powered off for some time the optimum sound quality is only reached after several minutes The critical circuits have to warm up to around 55 degrees Celsius 131 degrees Fahrenheit When the am...

Страница 7: ...e sonic improvement when the proper grounding is found is obvious and worth the try 7 SAFETY FEATURES The GOLDMUND MIMESIS 29 4 amplifier provides sophisticated features to protect the amplifier and t...

Страница 8: ...the temperature has reached such a level before operating the amp again Protection against short circuits If one output is short circuited by accident and the current becomes too high the AC fuse may...

Страница 9: ...ustable input sensitivity on the back panel Input impedance 10 52 kOhms GROUP DELAY Propagation delay 100 ns stable with frequency from DC to 200 kHz DISTORTION Figures valid for all levels from 0 to...

Страница 10: ...Display to show Input attenuation or inside temperature Led display for temperature DC offset or HF protection Led display for Power on operating mode Led display for Power on standby mode REAR PANEL...

Отзывы: