background image

REAR PANEL CONNECTORS AND CONTROLS : 
 

  D-Sub 9 pin socket for RS232 serial link. 

  Signal grounding post (black) and earth post (yellow/green) linkable by 

switch. 

  3 pairs of analogue RCA output connectors (right and left). 

  7 sets of digital input (1 x RCA SPDIF and 1 x XLR AES/EBU) and 2 

outputs for       digital tape loops. 

 
 
POWER SUPPLY : 
 

  Power transformers molded in a decoupled mechanical block with 

separate Mechanical Grounding transmission through the 2 left feet. 

  4 separate transformers.  

  8 separately regulated power supplies. 

  Nominal AC line voltage : 117 V or 234 V. 

  Input voltage range : +/- 15%. 

  Maximum power consumption : 55 W. 

 
 
GROUNDING :   
 

  Separated ground and earth connections to control ground loops. 

 
 
SIZE AND WEIGHT : 
 

  44 cm W x 43 cm D x 10.7 cm H. 

 20 

kg. 

 
WARRANTY  :  
 

 

3 years parts and labor

 
 

User manual – Goldmund MIMESIS 20M D/A CONVERTER 

P14 

Содержание MIMESIS 20M

Страница 1: ...____________________________________________________________________________________________________________________________________________ _________ _____________________________ ___________________...

Страница 2: ...SIS 20M D A CONVERTER Goldmund was founded in 1978 and has ever since been dedicated to the accurate reproduction of sound and image At Goldmund we strive to lead in the creation development and manuf...

Страница 3: ...e high bandwidth and ultra high bits capability which are or will become necessary for an accurate conversion of the today s best digital messages as well as tomorrow s new formats Only careful instal...

Страница 4: ...ns and all amateurs who demand the very best in recording transcription we strongly recommend the use of a top quality CD transport unit DVD transport or DAT machine since most of the digital signal i...

Страница 5: ...r if you use a coaxial cable link and the CD DVD transport is not perfectly matched to the SPDIF interface specifications a short distance is mandatory If you want to achieve the best possible sonic r...

Страница 6: ...The converter is and remains on power as soon as the power switch located on the back panel is turned on For best sonic results Goldmund recommends to leave the converter powered on permanently The u...

Страница 7: ...d the input output loop accordingly The digital outputs of the Mimesis 20M can be used to record on a digital tape machine They are connected in parallel except when the connected tape machine is moni...

Страница 8: ...ource is selected and transmitted to the converter circuitry The corresponding green Led indicates this selection If a source is connected the unit will first analyze the signal and finally turn the u...

Страница 9: ...In order to avoid any definition loss the maximum listening level must absolutely be set by the power amplifier level adjustment when the level is at maximum on the Mimesis 20M The attenuation circuit...

Страница 10: ...DIF default or the XLR AES EBU input for each input If an optional optical input module is present selects automatically displayed Toslink or ATT Tape In 1 selects which input channel sources are tape...

Страница 11: ...and balance adjustment Choose on the up down key The input 4 to 7 may be receiving an optional optical input module with Toslink or ATT To indicate this option is present select the input number and c...

Страница 12: ...uilt in remote control for volume and input selection The absolute phase can also be controlled by remote The power key of the remote actually activates the Standby Function The Mute circuit can also...

Страница 13: ...ble to replace up to 5 of the input modules by a special one providing different standard like ATT Optical Toslink Optical etc 2 Digital Outputs for tape loops with full monitoring capability both in...

Страница 14: ...OTE CONTROL RC5 Standard remote system compatible with standard programmable remote control transmitter Selection of the source and the recorded source Output level and balance control Absolute phase...

Страница 15: ...WER SUPPLY Power transformers molded in a decoupled mechanical block with separate Mechanical Grounding transmission through the 2 left feet 4 separate transformers 8 separately regulated power suppli...

Отзывы: