Goldmund METIS 8 Скачать руководство пользователя страница 6

 

GOLDMUND METIS 8 – 2-channel Acoustic Processor - 6 

PROCESSOR LOCATION & COOLING 

 
 
Select a very rigid support for your Goldmund Metis 8. 
 
The distance between the Metis 8, the speaker, the amplifier and the active Metis speakers 
is  usually  not  critical  since  the  signal  is  carried  in  the  digital  domain.  However,  you  must 
use the “Goldmund Lineal™” cable in order to maintain the time accuracy of the signal. For 
some  high  impedance  output  analog  sources,  a  short  distance  to  the  processor  is 
mandatory. 
 
If  you  want  to  achieve  the  best  possible  sonic  result,  select  a  position  on  a  shelf  or  on  a 
piece  of  furniture  where  the  processor  is  isolated  from  vibrations  of  mechanical 
components, such as the CD transport itself. 
 
You  must  also  be  careful  to  locate  your  Metis  8  in  a  very  well  ventilated  location.  When 
powered  on,  the  Metis  8,  as  all  high  quality  electronic  equipment,  generates  a  significant 
amount of heat, which has to be evacuated by natural ventilation. 

 
 

 
 

POWER SUPPLY

 

 
 
The Metis 8 uses multiple power supplies developed by Goldmund to provide totally 
separate voltage to each part of the digital and analog circuitry. 
 
The Metis 8 Acoustic Processor will function properly for main line voltages indicated page 
13 (see rubric Power for more details).  
 
The power supply unit tolerates both 50 & 60 Hz mains. 
 
 

 

 

Содержание METIS 8

Страница 1: ...USER MANUAL GOLDMUND METIS 8 2 channel Acoustic Processor...

Страница 2: ...ed in 1978 and has ever since been dedicated to the accurate reproduction of sound and image At Goldmund we strive to lead in the creation development and manufacture of the industry s most advanced t...

Страница 3: ...ntents 1 PRELIMINARIES 5 2 UNPACKING 5 3 PROCESSOR LOCATION COOLING 6 4 POWER SUPPLY 6 5 FIRST INSTALLATION CONNECTIONS 7 7 FRONT PANEL FUNCTIONS 11 8 REMOTE CONTROL 11 9 CLEANING 12 10 TECHNICAL DATA...

Страница 4: ...io multi channel signals Only careful use can provide all the satisfaction you are expecting All handling must be performed according to the following instructions to avoid deterioration of the proces...

Страница 5: ...and precise impedance SPDIF cables in digital to keep the time integrity that the best systems may provide Goldmund recommends using the digital Goldmund Lineal cable 2 UNPACKING You will find in the...

Страница 6: ...lect a position on a shelf or on a piece of furniture where the processor is isolated from vibrations of mechanical components such as the CD transport itself You must also be careful to locate your M...

Страница 7: ...red ON permanently When turned ON via the back panel power switch the unit accomplishes a self test run via its internal software then a software routine successively tests the modules inside the mach...

Страница 8: ...uality of your Metis system A standard configuration is available from the Goldmund Universal Configurator with corresponding speakers Please contact your authorized Goldmund retailer to assist you to...

Страница 9: ...dicates CF as shown on the picture bellow it means that the Metis 8 does not have a configuration loaded Please contact your authorized Goldmund retailer to assist you to set up your unit To play audi...

Страница 10: ...4 SOURCE AND SPEAKERS CONNECTION Ctd Once the complete audio system has been connected the power cords may be plugged and the various devices power supplies turned on Note Simply plugging its power c...

Страница 11: ...ute circuit can also be activated via the remote To mute or un mute the Metis 8 with the remote press the MUTE STBY key briefly To put the Metis 8 in Standby mode press the MUTE STBY key continuously...

Страница 12: ...gital inputs optical toslink up to 96 kHz 1 digital input USB up to 48 kHz PCM Stereo only The audio format supported are PCM 44 1kHz to 96kHz Dolby Digital DTS DTS CD AAC DIGITAL OUTPUTS DIGITAL OUTP...

Страница 13: ...tely regulated power supplies Nominal AC line voltage 117V or 234V 10 Maximum power consumption 8W Fuse 100mA 250V slow blow SIZE AND WEIGHT SIZE AND WEIGHT SIZE AND WEIGHT SIZE AND WEIGHT 370 W x 325...

Страница 14: ...te the appliance so that its location or position does not interfere with its proper ventilation 8 Heat Site the appliance away from heat sources such as radiators heaters stoves or other appliances i...

Страница 15: ...to provide some protection against voltage surges and static build up In the USA see article 810 of the National Electrical Code ANSI NFPA 70 concerning installation requirements 16 Unplug this appar...

Страница 16: ...Key 1 Active Balance 2 Mute Standby 3 NC 4 Left Balance 5 NC 6 Right Balance 7 Volume Up 8 Volume Down A Analog Input 1 B Analog Input 2 C Analog Input 3 D Digital Input 4 E Digital Input 5 F Digital...

Отзывы: