background image

Installation

Installation

Installation

Installation

Installation

Direct mounting on control

1.

  Disconnect power from SP control

2.

Remove the setpoint access panel from the
control cover.

3.

Feed TD-30 cable through the cover and
plug into the phone jack type connector on
the SP control (located to the left of the
setpoint adjustment knob).

4

Tuck the TD-30 cable by folding it and
pushing the slack down into the control,
making sure not to block the back of the
setpoint access hole.

5.

Now snap the TD-30 into the front panel of
the control.

6.

Restore power and check operation of the
control.  The setpoint can be adjusted using
the 1/8" Allen wrench through the access
hole in the TD-30.

Panel Mounting

1.

Cut a 3.94" x 1.5" (3 15/16" x 1 1/2")
rectangular opening in the panel.  Panel
thicknesses from .030" to .190" (3/16") are
suitable.

2.

Connect an extension cable between the
TD-30 and the SP-30/30D/300. Refer to
"TD-30 extension cables" section for more
information.

Wall mounting

1.

The MK-1 wallplate allows the TD-30 to be
flush mounted on a wall over a 3 gang

electrical box.  Alternatively, the MK-2
bracket allows the TD-30 to be mounted
onto a wall without penetrating the wall
surface.

Both the MK-1 and MK-2 mounting plates
must be ordered separately and are avail-
able at your Goldline dealer

2.

Connect an extension cable between the
TD-30 and the SP-30/30D/300. Refer to
"TD-30 extension cables" section for more
information.

TD-30 Extension Cables

Two types of extension cables can be used to
mount the TD-30 remote from the control:

Male/Female type: This phone cable has one male
jack and one female jack.  Plug the TD-30's short
cable into the female jack and plug the male jack
into the SP-30/30D/300 control.

Male/Male type: This phone cable has two male
jacks.  Remove the short cable from the TD-30 by
reaching into the small access hole in the rear of
the display, depressing the jack tab, and gently
pulling.  Plug one male end into the TD-30 and the
other into the SP-30/30D/300 control.

Custom Length: A male/male extension cable can
be assembled by following the diagram below.
Connectors, cable and assembly tools can com-
monly be found at electrical supply outlets.  Note
that each conductor's position on one jack, differs
from the other.  Wire accordingly.

2

2

3

3

4

4

5

5

B L K

R E D

G R N

Y E L

T D -30  C u sto m  E xtension  C able

T

D

3

0

B

.CDR

4  w ire  flat phon e cab le

5 00   ft 

m axim u m

R J -11

C o n ne ctor

R J -11

C o n ne ctor

Page 2

Отзывы: