Goldline GL2BZLPG Скачать руководство пользователя страница 4

4

 

Goldline N12- manual-ULPG June 2016

 

 

INSTALLATION INSTRUCTIONS

 

DATA PLATE DETAILS:

 

CHECK THAT THE DATA PLATE SHOWS THAT THE APPLIANCE IS SUITABLE FOR THE 

AVAILABLE GAS SUPPLY. IMPORANT: VERIFY GAS TYPE WITH LOCAL GAS NETWORK 

OPERATOR BEFORE CONNECTION OF THIS APPLIANCE.

 

 

 

1. Room Ventilation

 

 

 

 

 

 

Not for use in Marine craft, caravans or Mobile homes unless

fitted with safety device.

 

 

 

 

2. Before installing the appliance check that the location provides the required 

clearances from combustible materials and if necessary provide protection to adjacent 

surfaces as required by the regulations. Make provision for the gas supply to be 

connected in the position shown in Diagram A.

 

3. Cut the opening in the bench top to the dimensions shown in diagram B.

 

4. Remove the hotplate from the carton.

 

Position of gas inlet: See diagram on page 3. Depth from top of glass to bottom of tray:

 

70mm excluding regulator

 

5. Install the hotplate in the cut-out (see diagram B on page 2). 

Note:

 

If clearance between side and rear walls and periphery of the burner is less than 250mm, 

the walls must be protected with a non-combustible material. The protection must extend 

a minimum distance of 450mm above the burner. Horizontal surfaces less than 650mm

 

vertically above the hotplate must also be protected.

 

 

6. Ensure that gas and electrical outlet are accessible with the appliance installed. 

The gas connection to the regulator is 1/2” BSP. Please ensure gas supply line to

 

 

 

 

This cooktop must be installed in a room that has permanent ventilation to effect the 

correct operation of the appliances and also to provide adequate ventilation.

This airflow must exceed 20m3 via permanent vented openings in the wall of the 

room and these must have a section of 100cm² minimum. They must be constructed

In a manner so as to avoid any possible blockages. The airflow can also be drawn

indirectly from an adjacent room provided it complies with any local regulations to 

vent any fumes outdoors.

the appliance is of adequate length to allow sufficient withdrawal of appliance for

service or disconnection. The connection must be annealed copper pipe or flexible 

hose (if permissible by local aythority).

The data plate is located on the tray floor.

 

Refer - Gas fitting Manual.

 Not Supplied (AS5601)

 

Содержание GL2BZLPG

Страница 1: ...WZLPG CAST GL4WZLPG CAST CAST CAST CAST INSTALLATION INSTRUCTIONS FOR FITTERS ONLY USER AND OPERATOR INSTRUCTIONS Installation must be in accordance with manufacturer s instruction relevant Gas Fitting Regulations or AS5601 Gas Installation regulations These instructions should be read carefully prior to initial use and retained in a safe place in order that full advantage can be taken of the feat...

Страница 2: ...2BZLPG GL302BZNG CAST GL302BZLPG CAST Diagram B Cut Out in mm 480 485 Diagram A Tray Dimensions in mm Model GL2BZNG GL2BZLPG GL2BZNG CAST GL2BZLPG CAST GL2WZNG GL2WZLPG GL2WZNG CAST GL2WZLPG CAST Diagram B Cut Out in mm Diagram A Tray Dimensions in mm Model GL3BZNG GL3BZLPG GL3BZNG CAST GL3BZLPG CAST GL3WZNG GL3WZLPG GL3WZNG CAST GL3WZLPG CAST GL3SSNG GL3SSLPG GL3SSNG CAST GL3SSLPG CAST Diagram B ...

Страница 3: ...ram B Cut Out in mm Diagram A Tray Dimensions in mm Model GL4BZNG GL4BZLPG GL4BZNG CAST GL4BZLPG CAST GL4WZNG GL4WZLPG GL4WZNG CAST GL4WZLPG CAST GL4SSNG GL4SSLPG GL4SSNG CAST GL4SSLPG CAST Diagram B Cut Out in mm Diagram A Model GL704BZNG GL704BZLPG GL704BZNG CAST GL704BZLPG CAST GL704WZNG GL704WZLPG GL704WZNG CAST GL704WZLPG CAST Diagram B Tray Dimensions in mm Cut Out in mm ...

Страница 4: ...e burner is less than 250mm the walls must be protected with a non combustible material The protection must extend a minimum distance of 450mm above the burner Horizontal surfaces less than 650mm vertically above the hotplate must also be protected 6 Ensure that gas and electrical outlet are accessible with the appliance installed The gas connection to the regulator is 1 2 BSP Please ensure gas su...

Страница 5: ...ed for town and natural gas Pressure test point This is provided in the gas regulator Remove the screw connect the hose from the pressure gauge Turn on the gas to the large burner and manually light the burner The pressure is shown on the data plate To increase the pressure loosen locking nut and turn clockwise Disconnect gauge and replace test point screw 9 Test the appliance The burner will igni...

Страница 6: ...LESS FITTED WITH SAFETY DEVICE WARNING DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION SOME PROPELLANT GASES CAN BREAK DOWN WHEN HEATED AND PRODUCE CORROSIVE VAPOURS WHICH WILL ATTACK SOME MATERIALS ARTICLES WHICH ARE MADE OF FLAMMABLE MATER SHOULD NOT BE STORED IN DRAWERS OR CUPBOARDS IMMEDIATELY BELOW THIS APPLIANCE THE SILICONE RUBBER GASKET SHOULD NOT BE REMOVE...

Страница 7: ... To replace electrode Remove screw from the clamp holding the electrode and thermocouple and note the adjustment setting height of each Replace electrode FAULT ISOLATION CHART FAULT CAUSES REMEDY Burner will not light 1 Air in gas line 2 Blockage in line 3 Ignition not sparking 4 Flame failure device faulty 5 Check the battery applicable to DC version 1 Purge gas line 2 Trace back and clear 3 Chec...

Страница 8: ... the glass plate An indicator motif advises which knob controls each burner The full on and pre set simmer BURNER OPERATION 1 Depress the required control knob anti clockwise to the FULL ON position 2 When the burner has ignited adjust the control knob to the required setting Flame adjustment is achieved by rotating the control knob further in an anti clockwise fashion BATTERY REPLACEMENT applicab...

Страница 9: ... Wash spill bowl regularly and clean dirt and grease in a weekly basis Check the burner port regularly for blockage especially if there is occurrence of spillage and clean them if necessary MAINTENANCE SCHEDULE It is recommended that to have the units serviced by an authorized person at least once a year Allow the hob cooker to cool before attempting to dismantle or clean it The glass plate is bes...

Страница 10: ...ity of fabric ignition which may result in personal injury MINOR TROUBLE SHOOTING Symptoms Please check the following NO IGNITION 1 Check if anything is obstructing the electrode metal tip 2 If 240 AC check if appliance is connected to electrical supply 3 If 1 5V battery check and replace battery if required NO GAS Check that the gas is turned on at the main meter BURNER FLAME NOT BURNING EVENLY C...

Страница 11: ...STALLED IN MARINE CRAFT OR IN CARAVANS IT SHALL NOT BE USED AS A SPACE HEATER SPARE PARTS SERVICE CONTACT NUMBERS For spare part and technical support enquires please call MANUFACTURER A VARD INDUSTRIES P L ADDRESS 58 60 Quantum Close South Dandenong Victoria 3175 Australia TEL 61 3 9799 9660 WEBSITE www goldlinecorp com au e mail info goldlinecorp com au Check the data label affixed to your unit ...

Страница 12: ...s steel Black White Glass Shape Rectangular Rectangular Curved Curved Rectagular Rectagular Rectagular Nos of hob 1 2 2 3 3 4 4 Gas Type NG LPG NG LPG HKTown Gas HKTown Gas HKTown Gas NG LPG NG LPG Heat input for burner kW Left Mj hr Centre Right 4 2 15 0 2 3 8 0 4 2 15 0 5 2 18 72 5 2 18 72 5 2 18 72 2 7 9 72 5 2 18 72 2 5 9 0 x 2 5 2 18 72 2 5 9 0 x 2 5 2 18 72 x 2 2 5 9 0 x 2 1 7 x1 5 2 18 72 x...

Отзывы: